Abstract
AE technique was applied to the static structural test of the composite wing structure to evaluate the structural integrity and damage. During the test, strain and displacements measurement technique were used to figure out for static structural strength. AE parameter analysis and source location technique were used to evaluate the internal damage and find out damage source location. Design limit load test, the 1st and 2nd design ultimate load tests and fracture test were performed. Main AE source was detected by an sensor attached on skin near by front lug. Especially, at the 1st design ultimate test, strain and displacements results didn't show internal damage but AE signal presented a phenomenon that the internal damage was formed. At the fracture test, AE activities were very lively, and strain and displacements results showed a tendency that the load path was changed by severe damage. The internal damage initiation load and location were accurately evaluated during the static structural test using AE technique. It is certified from this paper that AE technique is useful technique for evaluation of internal damage at static structural strength test.
복합재 날개 구조물에 대한 구조 건전성 및 손상을 평가하기 위하여 정적 구조강도시험에 음향방출(AE)법이 응용되었다. 시험중 스트레인과 변위측정기법을 통하여 정적구조강도를 확인하였고, 음향방출요소 분석과 위치표정기법을 통하여 구조물의 내부 손상을 평가하고 손상위치를 찾을 수 있었다. 시험은 설계제한하중시험, 2차에 걸친 설계극한 하중시험, 파단시험이 수행되었다. 주요한 AE신호는 front lug근처의 표면에 부착된 센서에 의하여 감지되었다. 특히 1차 설계극한하중시험에서 스트레인 및 변위결과는 내부 손상을 보이지 않았으나 AE신호는 내부 손상이 이미 형성된 현상을 나타내었다. 파단시험에서는 AE활성도가 매우 활발하였고, 스트레인 및 변위의 결과는 심한 손상에 의하여 하중경로가 바뀌는 경향을 나타내었다. 음향방출법을 적용하여 정적 구조시험이 진행되는 동안 내부손상이 발생되는 하중과 위치를 정확하게 평가할 수 있었다. 본 연구로부터 음향방출법은 정적 구조강도시험에 있어 내부 손상을 평가하는데 유용한 기법임이 확인되었다.