References
- B. M. Rogina and B. Vojnovic, 'Application of optical fiber sensors for radiation dosimetry', Radiation Measurements, vol. 26, no. 4, pp. 599-602, 1996 https://doi.org/10.1016/1350-4487(96)00032-7
- T. Aoyama, S. Koyama, M. Tsuzaka, and H. Maekoshi, 'Depth-dose measuring device using a multichannel scintillating fiber array for electron beam therapy', Nagoya University College of Medical Technology, Daikokminai, Higashi-ku, Nagoya 461, Japan, pp. 1235 -1239, 1997
- K. W. Jang, D. H. Cho, W. J. Yoo, S. H. shin, H. S. Kim, S. H. Chung, B. Lee, H. Cho, and S. Kim, Development of two-dimensional fiber-optic radiation sensor for high energy photon beam therapy dosimetry', J. Nuclear Science and Technology, 5, pp. 466-469, 2008.
- D. H. Cho, K. W. Jang, W. J. Yoo, S. C. Chung, G. R Tack, G. M. Eom, B. Lee, H. Cho, and S. Kim, 'Performance evaluation of one-dimensional fiber-optic radiation sensor for measuring high energy electron beam using a cahrge-coupled device', J. Nuclear Science and Technology, 5, pp. 477-480, 2008
- I. Kwan, W. J. Yoo, D. H. Cho, K. W. Jang, S. H. shin, M. Carolan, M. Lerch, V. Perevertaylo, and A. Rosenfeld, 'Comparison of the New MOSkin Detector and Fiber Optic Dosimetry System for Radiotherapy', J. Nuclear Science and Technology,5, pp. 518-521, 2008
- A. S. Beddar, T. J. Kinsella, A. Ikhlef, and C. H. Sibata, 'A miniature “scintillator-fiberoptic-PMT” detector system for the dosimetry of small fields in streotactic radiosurgery' IEEE Trans. Nucl. Sci. vol. 48, no. 3, pp. 924-928, 2001 https://doi.org/10.1109/23.940133
- L. Archambault, A. S. Beddar, L. Gingras, F. Lacroix, R. Roy, and L. Beaulieu, 'Water-equivalent dosimeter array for small-field external beam radiotherapy', Med. Phys. 34, pp. 1583, 2007 https://doi.org/10.1118/1.2719363
- A. S. Beddar, 'plastic scintillation dosimetry and its application to radiotherapy', Radiation Measurements. 41, pp. S124 2007 https://doi.org/10.1016/j.radmeas.2007.01.002
- Y. M. Hwang, D. H. Cho, B. Lee, H. S. Cho, and S. Kim, 'Fabrication and characterization of plastic fiber-optic radiation sensor tips using inorganic scintillator material', J. Korean Sensors Society, vol. 14, no. 4, pp. 244-249, 2005 https://doi.org/10.5369/JSST.2005.14.4.244
- D. H. Cho, K. W. Jang, W. J. Yoo, B. Lee, H. S. Cho, and S. Kim, 'Fabrication and performance evaluation of one-dimensional fiber-optic radiation sensor for X-ray profile irradiated by clinical linear accelerator', J. Korean Sensors Society, vol. 16, no. 1, pp. 33-38, 2007 https://doi.org/10.5369/JSST.2007.16.1.033
- W. R. Hendee, G. S. Ibbott, and E. G. Hendee, 'Radiation therapy physics', 3rd ed. John Wiley & Sons, Inc., pp. 130, 2005
- A. S. Beddar, T. R. Mackie, and F. H. Attix, 'Water-equivallent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration', Phys. Med. Biol. 37, pp. 1883-1900, 1992 https://doi.org/10.1088/0031-9155/37/10/006
- A. S. Beddar, T. R. Mackie, and F. H. Attix, 'Water-equivallent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements', Phys. Med. Biol. 37, pp. 1901-1913, 1992b
- Faiz M. Khan, 'The physics of radiation therapy', 2nd ed. Williams & Wilkins, Baltimore, pp. 183, 1994
Cited by
- Measurement of Relative Depth dose of Therapeutic Photon Beam Using One-Dimensional Fiber-Optic Phantom Dosimeter vol.20, pp.2, 2011, https://doi.org/10.5369/JSST.2011.20.2.96