안와벽 재건술 시행 후 평가방법으로서 초음파의 효용성

Effectiveness of the ultrasonography in the evaluation following orbit wall reconstruction

  • 김창윤 (조선대학교 의과대학 성형외과학교실) ;
  • 양정열 (조선대학교 의과대학 성형외과학교실) ;
  • 천지선 (조선대학교 의과대학 성형외과학교실) ;
  • 문재원 (조선대학교 의과대학 성형외과학교실)
  • Kim, Chang Yun (Chosun University College of Medicine Department of Plastic and Reconstructive Surgery) ;
  • Yang, Jeong Yeol (Chosun University College of Medicine Department of Plastic and Reconstructive Surgery) ;
  • Cheon, Ji Seon (Chosun University College of Medicine Department of Plastic and Reconstructive Surgery) ;
  • Moon, Jae won (Chosun University College of Medicine Department of Plastic and Reconstructive Surgery)
  • 발행 : 2009.07.15

초록

Purpose: Blow out fracture resulting from facial trauma is of high frequency among facial bone fractures, and can cause severe complications. So, proper management and close observation after operation are needed. So far, Computed tomography has been the best choice in the evalution following orbit wall reconstruction. However, cost - effectiveness, accessibility to patients and hazard of radiation exposure of computed tomography require supplementary measure for the evaluation following orbit wall reconstruction. This study was performed to describe the effectiveness of ultrasonography in the evalution following orbit wall reconstruction. Methods: A retrospective study was performed on 40 patients who underwent orbit wall reconstruction from June, 2008 to July, 2008. The patients' ages ranged from 13 to 65 years (mean 27.5 years), and this group was compsoed of 27 male and 13 female patients. The follow up period ranged from 2 weeks to 28 weeks (mean 11weeks). Preoperatively, all fractures were diagnosed using computed tomography. Ultrasonography for all cases, and computed tomography for 2 cases were performed for evaluation following orbit wall reconstruction. Results: Reduction of herniated orbital soft tissue and orbit implant was identified by using ultrasonography in 38 cases out of 40 cases. In other cases which we could not identify the orbit implant, computed tomography was performed. Con clusion: Compared to computed tomography, ultrasonography is simple, inexpensive and convenient method. Ultrasonography can be used as supplementary measure to computed tomography in the evaluation following orbit wall reconstruction for elective patients.

키워드

참고문헌

  1. Jeong SH, Shin SH, Park HS, Koo SH: Measurement analytical study of computed tomography of the orbital structure in acute blow-out fracture. J Korean Soc Plast Reconstr Surg 34: 44, 2007
  2. Lee JG, Kweon YD, Kim CS, Ha JW, Kim HC: Orbital volume change measured by computed tomography in blow out fracture. J Korean Soc Plast Reconstr Surg 27: 437, 2000
  3. Ban TS, Na KS, Ji NC: Usefulness of two-dimensional CT & Three-dimensional CT in blow-out fracture. J Korean Ophthalmol Soc 40: 639, 1999
  4. Smith B, regan WF Jr: Blow-out fracture of the orbit: mechanism and correction of internal orbital fracture. Am J Ophthalmol 44: 733, 1957
  5. Fujino T: Experimental 'blowout' fracture of orbit. Plast Reconstr Surg 54: 81, 1974 https://doi.org/10.1097/00006534-197407000-00010
  6. Emery JM, Noorden GK, Sclernitzauer DA: Orbital floor fractures: long-term follow-up of cases with and without surgical repair. Trans Am Acad Ophthalmol Otolaryngol 75: 802, 1971
  7. Grove AS Jr, Tadmor R, New PF, Momose KJ: Orbital fracture evaluation by coronal computed tomography. Am J Ophthalmol 85: 679, 1978
  8. Kim TM, Park DH, Han DG, Ahn KY: The effectiveness of MRI in blow out fracture. J Korean Soc Plast Reconstr Surg 27: 223, 2000
  9. Gilbard SM, Mafee MF, Lagouros PA, Langer BG: Orbital Blowout fractures, the prognostic significance of computed tomography. Ophthalmol 92: 1523, 1985
  10. Jank S, Deibl M, Strobl H, Oberrauch A, Nicasi A, Missmann M, Bodner G: Intrarater reliability in the ultrasound diagnosis of medial and lateral orbital wall fractures with a curved array transducer. J Oral Maxillofac Surg 64: 68, 2006
  11. Jank S, Emshoff R, Etzelsdorfer M, Strobl H, Nicasi A, Norer B: Ultrasound versus computed tomography in the imaging of orbital floor fractures. J Oral Maxillofac Surg 62: 150, 2004 https://doi.org/10.1016/j.joms.2003.01.004
  12. Schabrun S, Chipchase L, Rickard H: Are therapeutic ultrasound units a potential vector for nosocomial infection? Physiother Res Int 11: 61, 2006 https://doi.org/10.1002/pri.329