Abstract
The objective of this study was to experimentally investigate the structural behavior of steel plate concrete walls with vertical ribs (SSC walls), to compare the experimental results with the currently applied evaluation equations, and to obtain information that would be useful in the development of design equations for SSC walls. SSC test specimens that were subjected to in plane shear forces and bending moments were fabricated and tested. The experimental results show that the effect of vertical ribs on the structural behavior of SSC walls may be neglected, and that the confinement effect of concrete on the steel plates on both sides of the walls was negligible. The comparison of the experimental results with the evaluation equations showed that the structural behavior of SSC walls under shear control is close to that of the evaluation equations, but that the behavior of SSC walls under larger bending moments is not very close to that of the evaluation equations. The current evaluation equations for USC walls may be applied to the design of SSC walls because the structural walls of nuclear power plants are not subjected to large in plane bending moments.
본 연구의 목적은 리브로 수직 보강된 강판-콘크리트 벽체(SSC벽체)의 구조적 거동을 실험적으로 조사하고 실험결과와 평가식에 의한 결과를 비교하여 평가식의 적정성을 평가하며 SSC벽체 설계기준의 설계식을 제정하기 위한 자료를 제시하는 것이다. 휨과 전단력을 받는 SSC시험체를 제작, 실험하고 그 결과를 분석하였다. SSC시험체의 거동은 리브가 없는 USC시험체의 거동과 유사하게 나타나 리브의 영향은 무시할 수 있으며 SSC벽체의 양면에 있는 강판에 의한 콘크리트의 구속효과는 무시할 수 있음을 알 수 있었다. 실험결과와 평가식을 비교한 결과 전단의 지배가 큰 시험체는 평가식과 매우 유사하게 나타났으며 휨의 영향이 큰 SSC시험체의 실험결과는 평가식과 다소 차이를 보였다. 원전구조물의 벽체는 전단력이 크게 작용하고 면내 휨모멘트의 영향이 작으므로 현재 개발된 SC벽체의 평가식을 SSC벽체의 설계에 적용할 수 있는 것으로 나타났다.