Optimization of Shroud Shape and Fan Location for Increasing Exhaust Flow Rate of Air Conditioner Outdoor Unit

실외기 토출 유량 증대를 위한 Shroud 형상 및 휀 위치 최적 설계

  • Ryu, Ki-Jung (School of Mechanical Engineering, Hanyang University) ;
  • Kim, Yoo-Yil (Energy system research center, KIMM) ;
  • Lee, Kwan-Soo (School of Mechanical Engineering, Hanyang University) ;
  • Cha, Woo-Ho (Air conditioning division, LS Mtron)
  • Published : 2009.11.10

Abstract

This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit by investigating the effects of fan location and shroud shape. To determine optimal design parameters, we investigated the exhaust flow rate by changing shroud height, fan height, fan guide height, and fan width. The 3rd order central composite design was performed to select three most important parameters affecting the exhaust flow rate. According to the result of response surface method, the exhaust flow rate of the optimum model increased by 6.25% compared to that of the base model.

Keywords

References

  1. Amgad, E., Daniel, F. and Ismael, R., 2003, Performance Analysis of Axial Fans in Residential Heat Pump Systems, ASHRAE Annual Meeting 4630, pp. 15-20
  2. Oh, K. J. and Kang, S. H., 1999, A Numerical Investigation of the Dual Performance Characteristics of a Small Propeller Fan Using Viscous Flow Calculations, Computers and Fluids, Vol. 28, pp. 815-823 https://doi.org/10.1016/S0045-7930(98)00035-8
  3. Oh, K. J. and Kang, S. H., 1995, Numerical Calculation of the Viscous Flow Around a Propeller Shaft Configuration, Int. j. Numerical Methods in Fluids, Vol. 21, pp. 1-13 https://doi.org/10.1002/fld.1650210102
  4. Youn, B. and Kim, N. H., 2007, An experimental investigation on the airside performance of fin-and-tube heat exchangers having sinusoidal wave fins, Heat Mass Transfer, Vol. 43, pp. 1249-1262 https://doi.org/10.1007/s00231-006-0210-y
  5. An, C. S. and Choi, D. H., 2004, Fow and heat transfer analysis for the performance improvement of Cross-flow fin-tube heat exchangers, Proceedings of the KSCFE Spring Annual Meeting, pp. 183-189
  6. Chung, Y. L., 2004, Analysis of Three-Dimensional Flow about the Outdoor Unit of a Gasengine Driven Heat Pump System, MS thesis, KAIST, Daejeon, Korea
  7. Donald, A. N. and Adrian, B., 2006, Convection in Porous Meadia, 3rd Ed., Springer, pp. 10-14