DOI QR코드

DOI QR Code

Quantitative Analysis of Modified Fermi-Direc Filter applied to Clinical MR Image

임상 MR영상에 적용된 변형 Fermi-Direc필터의 정량적 평가

  • 김기홍 (춘해보건대학 방사선과) ;
  • 김동현 (부산대학교 영상의학과)
  • Published : 2009.11.28

Abstract

Filtering has been used to improve the image quality not only in MRI but in most image processing fields. In this paper, modified Fermi-Direc filter was transformed in various shapes, and then the optimum shape was designed. In addition, Newly made filter was applied in real clinic, which showed the obvious improvement in image quality. In conclusion, filtered image was superior to original image in contrast and sharpness. Then, this was proved by the histogram of R, G, B channel used for the quantitative analysis.

영상처리 분야에서 필터링은 특정 목적에 따른 영상의 화질 개선을 위해 사용되고 있으며, 자기공명영상 분야에서도 여러 가지 필터들이 영상의 질적 향상을 위해 사용되고 있다. 본 논문에서는 최근 연구되어진 변형된 Fermi-Direc 필터를 여러 가지 형태로 다시 변형해 보고 가장 최적화된 형태를 도출해 보았다. 또한 이렇게 제작된 필터를 현재 병원에서 사용되고 있는 MR장비로 환자를 통해서 얻어진 임상 영상(original image)에 적용하였다. 그 결과 임상 영상(original image)들이 필터를 통과한 후 육안으로 보았을 때 화질이 개선되어진 것을 알 수 있었으며, 이들의 정량적인 평가를 위해 각 영상들의 R, G. B 채널의 히스토그램을 구하였다. 결론적으로, 질환에 따른 차이는 다소 있었으나 original image에 비해 필터를 적용한 후 얻어진 영상의 명암비와 선명도가 더 우수한 결과를 보였다. 따라서 변형된 Fermi-Filter의 사용이 실제 환자의 질병을 정확히 진단하여 치료하는데 기여할 수 있음을 알 수 있었다.

Keywords

References

  1. M. T. Vlaardingerbroek, J. A. den Voer, Magnetic Resonance Imaging, Springer, 1996.
  2. R. Gonzalez and R. Woods, Digital Image Processing, Addison-Wesley, Reading, MA. 1992.
  3. D. Geman and C. Yang, "Nonlinear image recovery with half-quadratic regularization," IEEE Transactions on Image Processing, vol. 4, no. 7, pp. 932-946, 1995. https://doi.org/10.1109/83.392335
  4. A. Jain, Fundamentals of Digital Image Processing, Prentice-Hall, 1986, Chap. 8.
  5. Mahesh, R.K. Gupta, R. Kalyanaraman, S.B. Rao, V.S.N. Kaliprasad, P.V.K. Reddy, R.K.S. Rathore, "Truncation artifact Reduction in MRI with a New Class of Filters.", Magnetic Resonnance in Medicine, 1993
  6. R. Archibald and A. Gelb, "A method to reduce the Gibbs ringing artifact in MRI scans while keeping tissue boundary integrity," IEEE Transactions on Medical Imaging, vol. 21, no. 4, pp. 305-319, 2002. https://doi.org/10.1109/TMI.2002.1000255
  7. R. T. Constable and R.M. Henkelman, "Data extrapolation for truncation artifact removal," Magnetic Resonance in Medicine, Vol.17, No.1, pp.108-118, 1991. https://doi.org/10.1002/mrm.1910170115
  8. S. Amartur and E. M. Haacke, "Modified iterative model based on data extrapolation method to reduce Gibbs ringing," Journal of Magnetic Resonance Imaging, Vol.1, No.3, pp.307-317, 1991. https://doi.org/10.1002/jmri.1880010309
  9. K. P. Pruessmann, M. Weiger, P. Bornert, and P. Boesiger, "Advances in sensitivity encoding with arbitrary k-space trajectories," Magnetic Resonance in Medicine, Vol.46, No.4, pp.638-651, 2001. https://doi.org/10.1002/mrm.1241