DOI QR코드

DOI QR Code

Study on Development and Application of CWS(Continuous Wall System) II Method

CWS(Continuous Wall System) II 공법의 개발 및 적응에 관한 연구

  • 임인식 ((주)한빛구조엔지니어링) ;
  • 이정배 ((주)한빛구조엔지니어링) ;
  • 최선영 ((주)한빛구조엔지니어링) ;
  • 이재호 ((주)한화건설 건축기술팀) ;
  • 우성우 ((주)한화건설 건축기술팀)
  • Published : 2009.02.20

Abstract

CWS I method developed to overcome the problems of frequent occurrence in the application of existing downward construction methods has demonstrated excellent efficiency. However, in the case of using slurry wall instead of SCW or CIP as a retaining wall, the improvements in connecting steel beams with the wall were demanded. Therefore, the study of CWS II method was carried out in order to accomplish the CWS I method reflecting its strong points and to ensure the settlement of a steel beam and to induce the diaphragm effect of a slab while reducing the degree of difficulty and the term of works and the cost of construction. In this paper, the concept and features of CWS II method as well as the progress of execution was discussed by comparing with existing methods.

Keywords

References

  1. 대우건설 건축기술팀, 탑다운 시공 매뉴얼, 1999
  2. 대한건축학회, 건축기술지침Ⅰ, 공간예술사, 2006
  3. 이동희, 탑다운 공법 시공, 기문당, p67, 2002
  4. 이정배 외, CWS 공법(buried wale Continuous Wall System)의 개발에 관한 연구, 한국건축시공학회 논문집, 제6권 제2호,p 200 https://doi.org/10.5345/JKIC.2006.6.2.081
  5. (주) 한빛구조 외, 매립형 철골띠장과 슬래브 강막작용을 이용하여 지하외벽의 연속시공이 가능하도록 한 지하 구조물 시공방법, 특허출원서, 2004
  6. (주)한빛구조엔지니어링 외, 슬러리월에서 슬래브 강막작용을 이용하여 토압 지지가 이루어지도록 한 지하 구조물의 역타구축 공법, 특허출원서, 2006
  7. (주)SPS, SPS 공사자료
  8. 토목공법연구회, 톱다운공법 구조와 시공, 도서출판 일광, 2005

Cited by

  1. Research about Researcher's Safety Ethnic Level and Improvement Extent of Safety Culture, Based on Organizational Safety Efforts vol.30, pp.3, 2015, https://doi.org/10.14346/JKOSOS.2015.30.3.123
  2. Development and Structural Assessment of Joints of Permanent Uni-Wall System and Floor Systems in Substructure vol.12, pp.2, 2012, https://doi.org/10.5345/JKIBC.2012.12.2.230