DOI QR코드

DOI QR Code

Experimental Study on Bond Strength of AFRP Rebar in Normal Strength Concrete

AFRP 보강근의 부착강도에 대한 실험적 연구

  • Published : 2009.02.28

Abstract

For reinforced concrete members, bond strength is one of the important factors between the two materials: the concrete and the reinforcing element. The bond strength of Aramid Fiber Reinforced Polymer (AFRP) rebar was tested using the pull-out method. Presented were comparison results of the bond strength between AFRP rebar and deformed steel bars from the test. Embedded lengths and diameters of the rebar were taken into account as parameters. The bond stress-slip responses and failure modes of AFRP rebar were evaluated. It was found that the bond stress-slip responses of AFRP rebar were similar to those of deformed steel bars. As the diameter of rebar increased, the pull-out load increased. In addition, it was shown that the bond strength of an AFRP rebar was approximately 54% compared with that of a deformed steel bar.

철근 콘크리트 부재에서 부착강도는 콘크리트와 보강근 사이에 중요한 요소 중 하나이다. 본 연구는 인발실험을 통해 AFRP 보강근의 부착강도에 대하여 실험하고, AFRP 보강근과 이형철근의 부착특성을 비교하여 나타내었다. 묻힘 길이와 보강근의 직경이 실험의 변수로 사용되었으며, 실험을 통해서 AFRP 보강근의 부착응력-미끌림 관계 및 파괴양상을 평가하였다. AFRP 보강근의 부착응력-미끌림 관계는 이형철근과 비슷한 양상을 보였으며, 보강근의 직경이 증가할수록 인발하중은 증가하나 부착응력은 비슷한 결과를 보였다. AFRP 보강근의 부착강도는 이형철근의 약 54%에 달하는 것으로 나타났다.

Keywords

References

  1. 김재생, 서대원, 신성우, 안종문, 한범석, “FRP 보강근을 사용한 콘크리트 보의 콘크리트 강도 효과” 대한건축학회지, 25(1), 2005.
  2. Okelo, R. and Yuan, R. L., “Bond Strength of Fiber Reinforced Polymer Rebars in Normal Strength Concrete,” Journal of composites for construction, 19(3), 2005
  3. 김태영, 박지선, 이정윤, 김긍환, “콘크리트 압축강도가 GFRP 복합재료 보강근의 부착강도에 미치는 영향,” 대한건축학회지, 21(12), 2005.
  4. 이상호, 안상호, “FRP 봉을 주근으로 사용한 콘크리트 보 부재의 휨 거동,” 대한건축학회지, 21(1), 2005.
  5. Malvar, L. J., Cox, J. V., and Cochran, K. B., “Bond between Carbon Fiber Reinforced Polymer Bars and Concrete. I : Experimental Study”, Journal of composites for construction, 7(2), 2003.
  6. 서대원, 한범석, 신성우, “FRP 보강근을 주근으로 사용한 일방향 콘크리트 슬래브의 거동,” 한국콘크리트학회지, 19(6), 2007. https://doi.org/10.4334/JKCI.2007.19.6.763
  7. ACI Guide Test Methods for Fiber-Reinforced Polymers (FRPs) for Reinforcing or Strengthening Concrete Structures, American Concrete. Institute Committee 440. 3R-04, 2004.
  8. ASTM Standard test method for Tensile Properties of Pulltruded Glass-Fiber-Reinforced-Plastic Rods, American Society of Testing Materials D 3916-02, 2002.
  9. Won, J. P., Park, C. G., Kim, H. H., Lee, S. W., and Jang, C. I., “Effect of fibers on the bonds between FRP reinforcing bars and high-strength concrete,” Journal of composites for construction, 2008