Total Hip Replacement Arthroplasty with the Mallory-Head System -Minimum 8-Year Follow-up Results-

Mallory-Head System을 이용한 인공 고관절 전치환술 -최소 8년 추시 결과-

  • Song, Joo-Hyoun (Department of Orthopedic Surgery, Catholic University College of Medicine, St. Vincent Hospital) ;
  • Lee, Ju-Yup (Department of Orthopedic Surgery, Catholic University College of Medicine, St. Vincent Hospital) ;
  • Jung, In-Ho (Department of Orthopedic Surgery, Catholic University College of Medicine, St. Vincent Hospital) ;
  • Yoo, Hyun-Ho (Department of Orthopedic Surgery, Catholic University College of Medicine, St. Vincent Hospital)
  • 송주현 (가톨릭대학교 의과대학 성빈센트병원 정형외과) ;
  • 이주엽 (가톨릭대학교 의과대학 성빈센트병원 정형외과) ;
  • 정인호 (가톨릭대학교 의과대학 성빈센트병원 정형외과) ;
  • 유현호 (가톨릭대학교 의과대학 성빈센트병원 정형외과)
  • Published : 2009.03.31

Abstract

Purpose: The purpose of this study was to assess the clinical and radiographic results of total hip arthroplasty with using the double tapered Mallory-Head system. Materials and Methods: The clinical and radiographic results of a consecutive series of 81 total hip replacements in 75 patients were reviewed at eight to twelve years (average: 9.8 years) postoperatively. The underlying diseases were avascular necrosis in 46 hips (57%), osteoarthritis in 12 hips (15%), RA in 9 hips (11%) and others. The clinical result was evaluated on the basis of the modified Harris hip score and the modified Merle d’Aubigne-Postel score. A radiographic analysis was also performed. Results: The average modified Harris hip score was improved from preoperative 56 points to postoperative 92 points. The average modified Merle d’Aubigne-Postel score was 15 points at the latest follow up, and 55 hips (68%) were classified as having clinical grades of excellent or good results. One acetabular component was revised because of loosening, and one was revised because of recurrent dislocation. Conclusion: The clinical and radiological evaluations of the total hip replacements using the Mallory-Head system showed good results.

목적: 이중 tapered 된 Mallory-Head 인공 대퇴 삽입물을 이용한 고관절 전치환술의 임상적, 방사선적 추시 결과를 확인하고자 하였다. 대상 및 방법: 인공 고관절 전 치환술을 받은 81예(75명)의 환자에 대한 평균 9.8년(8~12년)까지의 수술 후 추시 결과를 분석하였다. 수술 전 진단은 46예(57%)가 대퇴 골두 무혈성 괴사, 12예(15%)에서 골관절염, 9예(11%)에서 류마티스 관절염 등이었다. 임상적 결과는 modified Harris 점수와 modified Merle d’Aubigne-Postel 점수로 평가하였고, 방사선학적 결과를 분석하였다. 결과: 평균 modified Harris hip score는 술 전 56점에서 술 후 92점으로 향상되었다. Modified Merle d’Aubigne-Postel score는 최종 추시에서 평균 15점으로 55예(68%)가 good 또는 excellent의 임상적 등급으로 분류되었다. 1예에서 비구컵의 해리로 인한 재치환술을 요하였으며, 1예는 반복적 탈구로 인한 재치환술을 시행하였다. 결론: Mallory-Head 인공 대퇴 시스템을 이용한 전 치환술의 중장기 임상적 및 방사선적 결과는 우수한 것으로 판단된다.

Keywords

References

  1. Bobyn JD, Pilliar RM, Cameron HU, Weatherly GC: The optimum pore size for the fixation of porous surfaced metal implants by the ingrowth of bone. Clin Orthop Relat Res, 150: 263-270, 1980.
  2. Bourne RB, Rorabeck CH, Burkart BC, Kirk PG: Ingrowth surfaces. Plasma spray coating to titanium alloy hip replacements. Clin Orthop Relat Res, 298: 37-46, 1994.
  3. Callaghan JJ, Dysart SH, Savory CG: The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series. J Bone Joint Surg, 70-A: 337-346, 1988.
  4. DeLee JG, Charnley J: Radiologic demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res, 121: 20-32, 1976.
  5. Dorr LD, Lewonowski K, Lucero M, Harris M, Wan Z: Failure mechanisms of anatomic porous replacement I cementless total hip replacement. Clin Orthop Relat Res, 334: 157-167, 1997.
  6. Emerson RH Jr, Snaders SB, Head WC, Higgins L: Effect of circumferential plasma-spray porous coating on the rate of femoral osteolysis after total hip arthroplasty. J Bone Joint Surg, 81-A: 1291-1298, 1999.
  7. Engh CA Jr, Culpepper WJ 2nd, Engh CA: Long term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty. J Bone Joint Surg, 79-A: 177-184. 1997.
  8. Engh CA, Massin P, Suthers KE: Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res, 257: 107-128, 1990.
  9. Goetz DD, Smith EJ, Harris WH: The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements, A retrospective matched-pair series, J Bone Joint Surg, 76-A: 1121-1129, 1994.
  10. Gosens T, van Langelaan EJ, Tonino AJ: Cementless mallory-head HA-coated hip arthroplasty for osteoarthritis in hip dysplasia. J Arthroplasty, 18: 401-410, 2003. https://doi.org/10.1016/S0883-5403(03)00063-9
  11. Gruen TA, MeNeice GM, Amstutz HC: "Modes of failure"of cemented stem-type femoral components. A radiographic analysis of loosening. Clin Orthop Relat Res, 141: 17-27, 1979.
  12. Haddad RJ, Jr. Skalley TC, Cook SD et al.: Clinical and roentgenographic evaluation of noncemented porouscoated anatomic medullary locking(AML) and porouscoated anatomic(PCA) total hip arthroplasties. Clin Orthop Relat Res, 258: 176-182, 1990.
  13. Head WC, Mallory TH, Emerson RH Jr: The proximal porous coating alternative for primary total hip arthroplasty. Orthopedics, 22: 813-815, 1999.
  14. Hedley AK, Gruen TA, Borden LS, Hungerford DS, Habermann E, Kenna RV: Two-year follow-up of the PCA noncemented total hip replacement. Hip, 225-250. 1987.
  15. Heekin RD, Callaghan JJ, Hopkinson WJ, Savory CG, Xenos JS: The porous-coated anatomic total hip prosthesis, inserted without cement. Results after five to seven years in a prospective study. J Bone Joint Surg, 75-A: 77-91, 1993.
  16. Jacobs JJ, Galante JO, Sumner DR: Local response to biomaterials: bone loss in cementless femoral stems. Instr Course Lect, 41: 119-125, 1992.
  17. Kaplan EL, Meier P: Nonparametric estimation from incomplete observations. J Am Statist Assn, 53: 457-481, 1958. https://doi.org/10.2307/2281868
  18. Kim YH, Kim VE: Results of the Harris-Galante cementless hip prosthesis. J Bone Joint Surg, 74-B: 83-87, 1992.
  19. Livermore J, Ilstrup D, Morrey B: Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg, 72-A: 518-528, 1990.
  20. Mallory TH, Lombardi AV Jr, Leith JR et al.: Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty. J Arthroplasty, 16: 49-54, 2001. https://doi.org/10.1054/arth.2001.28721
  21. Mallory WJ, Jasty M, Harris WH, Galante JO, Callaghan JJ: Endosteal erosion in association with stable uncemented femoral component. J Bone Joint Surg 72-A: 1025-1034, 1990.
  22. Martell JM, Pierson RH 3rd, Jacobs JJ, Rosenberg AG, Maley M, Galante JO: Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement. J Bone Joint Surg, 75-A: 554-571, 1993.
  23. Matta JM, Mehne DK, Roffi R: Fractures of the acetabulum. Early results of a prospective study. Clin Orthop Relat Res, Apr: 241-250, 1986.
  24. McLaughlin JR, Lee KR: Total hip arthroplasty with an uncemented femoral component. Excellent results at tenyear follow-up. J Bone Joint Surg, 79-B: 900-907, 1997.
  25. Mulliken BD, Bourne RB, Rorabeck CH, Nayak N: Results of the cementless Mallory-Head primary total hip arthroplasty: a 5 to 7 year review. Iowa Orthop J, 16: 20-34, 1996.
  26. Park MS, Choi BW, Kim SJ, Park JH: Plasma spraycoated Ti femoral component for cementless total hip arthroplasty. J Arthroplasty, 18: 626-630, 2003. https://doi.org/10.1016/S0883-5403(03)00203-1
  27. Pilliar RM: Porous surfaced metallic implants for orthopedic application. J Biomed Mater Res, 21(A1 Suppl): 1-33, 1987. https://doi.org/10.1002/jbm.820210106
  28. Ovre S, Sandvik L, Madsen JE, Roise O: Modification of the Harris hip score in acetabular fracture treatment. Injury, 38(3): 344-349, 2007. https://doi.org/10.1016/j.injury.2006.04.129
  29. Ragab AA, Kraay MJ, Goldberg VM: Clinical and Radiologic Outcomes of Total Hip Arthroplasty with Insertion of an Anatomically Designed Femoral Component without Cement for the Treatment of Primary Osteoarthritis. A study with a minimum of six years of follow-up. J Bone Joint Surg, 81-A: 210-218, 1999.
  30. Ritter MA, Fechtman RW: Distal cortical hypertrophy following total hip arthroplasty. J Arthroplasty, 3: 117-21, 1988. https://doi.org/10.1016/S0883-5403(88)80076-7
  31. Rogers A, Kulkarni R, Downes EM: The ABG hydroxyapatite-coated hip prosthesis: one hundred consecutive operations with average 6-year follow-up. J Arthroplasty, 18: 619-625, 2003. https://doi.org/10.1016/S0883-5403(03)00208-0
  32. Rosenberg A: Cementless total hip arthroplasty: femoral remodeling and clinical experience. Orthopedics, 12: 1223-1233, 1989.
  33. Sakalkale DP, Eng K, Hozack WJ et al.: Minimum 10 year results of a tapered cementless hip replacement. Clin Orthop Relat Res, 362: 138-144, 1999.
  34. Santavirta S, Hoikka V et al.: Aggressive granulomatous lesions in cementless total hip arthroplasty. J Bone Joint Surg, 72-B: 980-984, 1990.
  35. Schmalzried TP, Jasty M, Harris WH: Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg, 74-A: 849-863, 1992.