DOI QR코드

DOI QR Code

Development of an Isotope-Dilution Flow-Injection Electrospray/ Mass Spectrometric Method for the Accurate Determination of Glucosamine in Pharmaceutical Formulation

  • Kim, Gui-Nam (Department of Chemistry, Kyungnam University) ;
  • Kim, Byung-Joo (Division of Metrology for Quality Life, Korea Research Institute of Standards and Science) ;
  • Ahn, Seong-Hee (Division of Metrology for Quality Life, Korea Research Institute of Standards and Science) ;
  • Hwang, Eui-Jin (Division of Metrology for Quality Life, Korea Research Institute of Standards and Science) ;
  • Kim, Yong-Seong (Department of Chemistry, Kyungnam University)
  • Published : 2009.02.20

Abstract

An isotope-dilution flow-injection electrospray/mass spectrometric method was developed for the accurate determination of glucosamine contents in pharmaceutical formulations. Samples were extracted by methanol. After spiking glucosamine-1-$^{13}C_1$ as an internal standard, the extracts were then analyzed by flow-injection ESI/MS in a selected ion monitoring (SIM) mode to detect [M+H]$^+$ ions of the analyte and its isotope analogue at m/z 180 and m/z 181, respectively. Confirmatory measurements were made by selectively monitoring the collisionally induced dissociation channels of m/z 180 $\rightarrow$ m/z 72 and m/z 181 $\rightarrow$73, respectively, to test the possibility of bias in the SIM method due to matrix interferences, but any significant bias in the SIM mode was not observed. Repeatability and reproducibility studies showed that the flow-injection ESI/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0 %. Other results for the method validation are reported.

Keywords

References

  1. Liang, Z.; Leslie, J.; Adebowale, A.; Ashraf, M.; Eddington, N. D. J. Pharm. Biomed. Anal. 1999, 20, 807 https://doi.org/10.1016/S0731-7085(99)00085-0
  2. Shao, Y.; Alluri, R.; Mummert, M.; Koetter, U.; Lech, S. J. Pharm. Biomed. Anal. 2004, 35, 625 https://doi.org/10.1016/j.jpba.2004.01.021
  3. Felson, D. T.; Zhang, Y. Arthritis. Rheum. 1998, 41, 1343 https://doi.org/10.1002/1529-0131(199808)41:8<1343::AID-ART3>3.0.CO;2-9
  4. Uebelhart, D.; Thonar, E. J.-M.; Zhang, J.; Williams, J. M. Osteoarthritis. Cartilage. 1998, 6 (Supplement A), 6 https://doi.org/10.1016/S1063-4584(98)80005-8
  5. Wu, Y.; Hussain, M.; Fassihi, R. J. Pharm. Biomed. Anal. 2005, 38, 263 https://doi.org/10.1016/j.jpba.2005.01.001
  6. Zhu, X.; Cai, J.; Yang, J.; Su, Q. Carbohydr. Research 2005, 340, 1732 https://doi.org/10.1016/j.carres.2005.01.045
  7. El-Saharty, Y. S.; Bary, A. A. Anal. Chim. Acta 2002, 462, 125 https://doi.org/10.1016/S0003-2670(02)00279-9
  8. Crespo, M. O. P.; Martínez, M. V.; Hernández, J. L.; Yusty, M. A. L. J. Chromatogr. A 2006, 1116, 189 https://doi.org/10.1016/j.chroma.2006.03.068
  9. Huang, T.-M.; Cai, L.; Yang, B.; Zhou, M.-X.; Shen, Y.-F.; Duan, G.-L. Biomed. Chromatogr. 2006, 20, 215
  10. Huang, T.-M.; Deng, C.-H.; Chen, N.-Z.; Liu, Z.; Duan, G.-L. J. Sep. Sci. 2006, 29, 2296 https://doi.org/10.1002/jssc.200600162
  11. Tekko, I. A.; Bonner, M. C.; Williams, A. C. J. Pharm. Biomed. Anal. 2006, 41, 385 https://doi.org/10.1016/j.jpba.2005.11.044
  12. Roda, A.; Sabatini, L.; Barbieri, A.; Guardigli, M.; Locatelli, M.; Violante, F. S.; Rovati, L. C.; Persiani, S. J. Chromatogr. B 2006, 844, 119 https://doi.org/10.1016/j.jchromb.2006.07.013
  13. Kim, B.; Kim, D. H.; Choi, J. O.; So, H.-Y. Bull. Korean Chem. Soc. 1999, 20, 910
  14. Jung, M.; Kim, B.; Boo, D. W.; So, H.-Y. Bull. Korean Chem. Soc. 2007, 28, 745 https://doi.org/10.5012/bkcs.2007.28.5.745
  15. Park, S.; Kim, B.; So, H.-Y.; Kim, Y.-J.; Kim, J. Bull. Korean Chem. Soc. 2007, 28, 737 https://doi.org/10.5012/bkcs.2007.28.5.737
  16. Jung, P. G.; Kim, B.; Park, S.-R.; So, H.-Y.; Shi, L. H.; Kim, Y. Anal. Bioanal. Chem. 2004, 380, 782 https://doi.org/10.1007/s00216-004-2846-0

Cited by

  1. Current literature in mass spectrometry vol.44, pp.9, 2009, https://doi.org/10.1002/jms.1494