Effect of the Third Electrode of a Needle-Mesh Airgap on Ionic Wind Generation

침대 그물전극간의 제3전극이 이온풍 발생에 미치는 영향

  • 황덕현 (경북대학교 대학원 전자전기컴퓨터학부) ;
  • 문재덕 (경북대학교 전자전기컴퓨터학부)
  • Published : 2008.11.01

Abstract

Cooling technologies using natural and forced convection are limited and operated in very low efficiency. The corona discharge is utilized as the driving mechanism for an ionic pump, which allows for air flow control and generation with low noise and no moving parts. These ideal characteristics of ionic pump give rise to variety applications. However, all of these applications would benefit from maximizing the flow velocities and efficiencies of the pumps. In this study a needle-mesh type ionic pump, with a ring type third electrode installed just near the needle point, has been investigated by focusing on elevating the ionic wind velocity and efficiency. As a result, the enhanced ionic wind velocity and increased power yield can be obtained with the proposed ionic pump with the third electrode.

Keywords

References

  1. B. Komeili, J.S. Chang, G.D. Harvel, C. Ching, 'Electrohydrodynamically Enhanced Capillary Evaporator,' International Symposium on New Plasma and Electrical Discharge Applications and on Dielectric Materials, pp. 11-16, August 2007
  2. F. Yang, N.E. Jewell-Larsen, D.L. Brown, K. Pendergrass, D.A. Parker, I.A. Krichtafovitch, A.V. Mamishev, 'Corona driven air propulsion for cooling of electronics, XIIIth International Symposium on High Voltage Engineering,' pp. 1-4, 2003
  3. PC Power and Cooling, Inc., 'Rotary fan efficiency for Intel processor fan,' January 2002
  4. F. Polak, 'New Micro-architecture Challenges in the Coming Generation of CMOS Process Technologies,' Micro 32, 1999
  5. R. Mestiri, R. Hadaji, S.B. Nasrallah, 'The electrical discharge as a source of a mechanical energy,' Desalination, Vol. 220, pp. 468-475, 2008 https://doi.org/10.1016/j.desal.2007.01.048
  6. H. Tsubone, B. Komeili, S. Minami, G.D. Harvel, K. Urashima, C.Y. Ching, J.S. Chang, 'Flow characteristics of de wire-non-parallel plate electrohydrodynamic gas pump,' Journal of Electrostatics, Vol. 66, pp. 115-121, 2008 https://doi.org/10.1016/j.elstat.2007.09.002
  7. M. Rickard, D. Dunn-Rankin, F. Weinberg, F. Carleton, 'Maximizing ion-driven gas flows,' Journal of Electrostatics, Vol. 64, 368-376, 2006 https://doi.org/10.1016/j.elstat.2005.09.005
  8. E. Moreau, G. Touchard, 'Enhancing the mechanical efficiency of electric wind in corona discharge,' Journal of Electrostatics, Vol. 66, pp. 39-44, 2008 https://doi.org/10.1016/j.elstat.2007.08.006
  9. J. Moon, J. Jung, S. Gum, 'The Effect of a Strip-type Third Electrode of a Wire-Plate Type Nonthermal Plasma Reactor on Corona Discharge and Ozone Generation Characteristics,' International Journal of Plasma Environmental Science and Technology. Vol. 2, No. 1, pp. 26-33, 2008