Abstract
UV lamp systems have been used for cleaning of display panels of TFT LCD or Plasma Display Panel (PDP). However, the needs for high efficient cleaning and low cost made high voltage plasma cleaning techniques to be developed and to be improved. Dielectric-Barrier Discharges (DBDs), also referred to as barrier discharges or silent discharges have been exclusively related to ozone generation for a long time. In this paper, a 6kW high voltage plasma power supply system was developed for LCD cleaning. The 3-phase input voltage is rectified and then inverter system is used to make a high frequency pulse train, which is rectified after passing through a high-power transformer. Finally, hi-directional high voltage pulse switching circuits are used to generate the high voltage plasma. Some experimental results showed the usefulness of atmospheric plasma for LCD panel cleaning.
UV 램프 시스템은 오랫동안 TFT LCD 나 PDP 의 패널 세정에 사용되어 왔으나, 저렴한 가격의 고성능 세정에 대한 필요성 때문에 고전압 플라즈마 세정에 대한 기술이 개발되고 그 성능이 향상되어 왔다. 장벽방전 (barrier discharge) 혹은 무성방전 (silent discharge)으로 불리는 유전체 장벽 방전 (Dielectric-Barrier Discharges, DBDs) 는 오존 발생기에 주로 이용되어 왔다. 본 논문에서는 LCD 세정용으로 6kW 급 고전압 플라즈마 발생장치를 구현하였다. 3상 입력전압을 직류로 정류한 뒤, 인버터 시스템에 의해 고주파 펄스로 바꾸고 고압 트랜스퍼머를 거쳐 다이오드로 정류한다. 마지막으로, 고압 플라즈마를 발생시키기 위해 양방향 고전압 펄스 스위칭회로가 사용되었다. 실험을 통해 상압 플라즈마가 LCD 패널 세정에 크게 유용함을 보였다.