참고문헌
- Kim, H. K. and B. S. Noh. 2002. Optimization of Sikhe processing using the obtained data by biosensor. Korean J. Food Sci. Technol. 34(1):65-72. (In Korean)
- Kim, J. H., D. H. Rhie, T. J. Kim and B. S. Noh. 1998. Development of biosensor for simultaneous determination of glucose, lactic acid and ethanol. Korean J. Food Sci. Technol. 30(1):22-34. (In Korean)
- Park, I. S., J. H. Kim, T. J. Kim, N. S. Kim and B. S. Noh. 1996. Simultaneous determination of glucose and ethanol of Takju by biosensor using dual cathode electrode. Korean J. Food Sci. Technol. 28(5):974-980. (In Korean)
- Rajendran, V. and J. Irudayaraj. 2002. Detection of glucose and lactose in milk with a microdialysis-coupled flow injection amperometric sensor. J. Dairy Sci. 85:1357-1361 https://doi.org/10.3168/jds.S0022-0302(02)74201-X
- Rhee, J. I. 1998. On-line monitoring of glucose and acetate by flow-injection analysis in Escherichia coli fermentation process. Korean J. Biotechnol. Bioeng. 13(3):244-250. (In Korean)
- Rocha, I. and E. C. Ferreira. 2002. On-line simultaneous monitoring of glucose and acetate with FIA during high cell density fermentation of recombinant E. coli. Analytica Chimica Acta. 462:293-304 https://doi.org/10.1016/S0003-2670(02)00347-1
- Ruzicka, J. and E. H. Hansen. 1975. Flow injection analysis. Part I. A new concept of fast continuous flow analysis. Analytica Chimica Acta. 78:145 https://doi.org/10.1016/S0003-2670(01)84761-9
- Schugerl, K., B. Hitzmann, H. jurgens, T. Kullick, R. Ulber and B. Weigal. 1996. Challenges in integrating biosensors and FIA for on-line monitoring and control. TIBTECH. 14:21-31 https://doi.org/10.1016/0167-7799(96)80910-3
- Song, D. B., H. S. Jung, S. K. Lee, D. H. Jung and S. W. Park. 2007. Performance evaluation of an auto sampling and filtering unit of substrate solution using a diaphragm pump. J. of Biosystems Engineering 32(4):263-268. (In Korean) https://doi.org/10.5307/JBE.2007.32.4.263
-
Song, D. B. and J. Irudayaraj. 2003. Measurement of glucose concentration using
$\mu$ FIA biosensor J. of Biosystems Engineering. 28(5):465-468. (In Korean) https://doi.org/10.5307/JBE.2003.28.5.465 - Werasak, S., W. Supinda, S. Pornpimol, T. Morakot and K. Krissanapong. 1999. Dual electrode signal-substracted biosensor for simultaneous flow injection determination of sucrose and glucose. Analytica Chimica Acta. 380:7-15 https://doi.org/10.1016/S0003-2670(98)00710-7
- White, S. F., I. E. Tothill, J. D. Newman and A. P. F. Turner. 1996. Development of a mass-producible glucose biosensor and flow-injection analysis system suitable for on-line monitoring during fermentation. Analytica Chimica Acta. 321:165-172 https://doi.org/10.1016/0003-2670(95)00514-5