Bone Cement Augmentation of Short Segment Fixation for Unstable Burst Fracture in Severe Osteoporosis

  • Kim, Hyeun-Sung (Department of Neurosurgery, Mok-Po Han Kook Hospital) ;
  • Park, Sung-Keun (Department of Neurosurgery, Mok-Po Han Kook Hospital) ;
  • Joy, Hoon (Department of Neurosurgery, Mok-Po Han Kook Hospital) ;
  • Ryu, Jae-Kwang (Department of Neurosurgery, Mok-Po Han Kook Hospital) ;
  • Kim, Seok-Won (Department of Neurosurgery, School of Medicine, Chosun University) ;
  • Ju, Chang-Il (Department of Neurosurgery, School of Medicine, Chosun University)
  • 발행 : 2008.07.28

초록

Objective : The purpose of this study was to determine the efficacy of short segment fixation following postural reduction for the re-expansion and stabilization of unstable burst fractures in patients with osteoporosis. Methods : Twenty patients underwent short segment fixation following postural reduction using a soft roll at the involved vertebra in cases of severely collapsed vertebrae of more than half their original height. All patients had unstable burst fracture with canal compromise, but their motor power was intact. The surgical procedure included postural reduction for 2 days and bone cement-augmented pedicle screw fixations at one level above, one level below and the fractured level itself. Imaging and clinical findings, including the level of the vertebra involved, vertebral height restoration, injected cement volume, local kyphosis, clinical outcome and complications were analyzed. Results : The mean follow-up period was 15 months. The mean pain score (visual analogue scale) prior to surgery was 8.1, which decreased to 2.8 at 7 days after surgery. The kyphotic angle improved significantly from $21.6{\pm}5.8^{\circ}$ before surgery to $5.2{\pm}3.7^{\circ}$ after surgery. The fraction of the height of the vertebra increased from 35% and 40% to 70% in the anterior and middle portion. There were no signs of hardware pull-out, cement leakage into the spinal canal or aggravation of kyphotic deformities. Conclusion : In the management of unstable burst fracture in patients with severe osteoporosis, short segment pedicle screw fixation with bone cement augmentation following postural reduction can be used to reduce the total levels of pedicle screw fixation and to correct kyphotic deformities.

키워드

참고문헌

  1. Alanay A, Acaroglu E, Yazici M, Oznur A, Surat A : Short-segment pedicle instrumentation of thoracolumbar burst fractures : does transpedicular intracorporeal grafting prevent early failure? Spine 26 : 213-217, 2001 https://doi.org/10.1097/00007632-200101150-00017
  2. Bedbrook GM : Stability of spinal fractures and fracture dislocations. Paraplegia 9 : 23-32, 1971 https://doi.org/10.1038/sc.1971.3
  3. Carl AL, Tromanhauser SG, Roger DJ : Pedicle screw instrumentation for thoracolumbar burst fractures and fracturedislocations. Spine 17 : S317-S324, 1992 https://doi.org/10.1097/00007632-199208001-00018
  4. Denis F : Spinal instability as defined by the three-column spine concept in acute spinal trauma. Clin Orthop Relat Res 189 : 65- 76, 1984
  5. Dick W, Kluger P, Magerl F, Woersdorfer O, Zach G : A new device for internal fixation of thoracolumbar and lumbar spine fractures: the' fixateur interne'. Paraplegia 23 : 225-232, 1985 https://doi.org/10.1038/sc.1985.38
  6. Gurwitz GS, Dawson JM, McNamara MJ, Federspiel CF, Spengler DM : Biomechanical analysis of three surgical approaches for lumbar burst fractures using short-segment instrumentation. Spine 18 : 977-982, 1993 https://doi.org/10.1097/00007632-199306150-00005
  7. Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS 3rd, Cook SD : Effects of bone mineral density on pedicle screw fixation. Spine 19 : 2415-420, 1994 https://doi.org/10.1097/00007632-199411000-00008
  8. Hasegawa K, Takahashi HE, Uchiyama S, Hirano T, Hara T, Washio T, et al : An experimental study of a combination method using a pedicle screw and laminar hook for the osteoporotic spine. Spine 22 : 958-962, 1997 https://doi.org/10.1097/00007632-199705010-00004
  9. Hu SS : Internal fixation in the osteoporotic spine. Spine 22 : 43S- 48S, 1997 https://doi.org/10.1097/00007632-199712151-00008
  10. Kim HS, Ju CI, Kim SW, Lee SM, Shin H : Balloon kyphoplasty in severe osteoporotic compression fracture; Is it a contraindication? Neurosurgery 60 : 1-6, 2007 https://doi.org/10.1227/01.NEU.0000257054.72246.A3
  11. Kramer DL, Rodgers WB, Mansfield FL : Transpedicular instrumentation and short-segment fusion of thoracolumbar fractures : a prospective study using a single instrumentation system. J Orthop Trauma 9 : 499-506, 1995 https://doi.org/10.1097/00005131-199509060-00007
  12. Krompinger WJ, Fredrickson BE, Mino DE, Yuan HA : Conservative treatment of fractures of the thoracic and lumbar spine. Orthop Clin North Am Jan 17 : 161-170, 1986
  13. McLain RF: The Biomechanics of long versus short fixation for thoracolumbar spine fractures. Spine 31 : S70-S79, 2006 https://doi.org/10.1097/01.brs.0000218221.47230.dd
  14. McLain RF, Sparling E, Benson DR : Early failure of shortsegment pedicle instrumentation for thoracolumbar fractures. A preliminary report. J Bone Joint Surg Am 75 : 162-167, 1993 https://doi.org/10.2106/00004623-199302000-00002
  15. Mumford J, Weinstein JN, Spratt KF, Goel VK : Thoracolumbar burst fractures. The clinical efficacy and outcome of nonoperative management. Spine 18 : 955-970, 1993 https://doi.org/10.1097/00007632-199306150-00003
  16. Sanderson PL, Fraser RD, Hall DJ, Cain CM, Osti OL, Potter GR : Short segment fixation of thoraxo lumbar burst fractures without fusion. Eur spine J 8 : 495-500, 1999 https://doi.org/10.1007/s005860050212
  17. Sasso RC, Cotler HB, Reuben JD : Posterior fixation of thoracic and lumbar spine fractures using DC plates and pedicle screws. Spine 16 : S134-S139, 1991 https://doi.org/10.1097/00007632-199103001-00019
  18. Shen WJ, Shen YS : Nonsurgical treatment of three-column thoracolumbar junction burst fractures without neurologic deficit. Spine 24 : 412-415, 1999 https://doi.org/10.1097/00007632-199902150-00024
  19. Soshi S, Shiba R, Kondo H, Murota K : An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 16 : 1335-1341, 1991 https://doi.org/10.1097/00007632-199111000-00015
  20. Tan JS, Wang JJ, Flood V, Rochtchina E, Smith W, Mitchell P : Cement augmentation of vertebral screws enhances the interface strength between interbody device and vertebral body. Spine 32 : 334-341, 2007 https://doi.org/10.1097/01.brs.0000253645.24141.21
  21. Wittenberg RH, Shea M, Swartz DE, Lee KS, White AA 3rd, Hayes WC : Importance of bone mineral density in instrumented spine fusions. Spine 16 : 647-652, 1991 https://doi.org/10.1097/00007632-199106000-00009
  22. Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field BT, Spencer CW : A biomechanical study of intrapedicular screw fixation in the lumbosacral spine. Clin Orthop Relat Res 203 : 99-112, 1986