Extracting 3D Geometry Parameters of Hip Joint for Designing a Custom-Made Hip Implant

맞춤형 인공관절 설계를 위한 인체 고관절의 3차원 형상 정보 추출

  • 서정우 (세종대학교 기계공학과 대학원) ;
  • 전용태 (세종대학교 기계공학과)
  • Published : 2008.06.30

Abstract

Total Hip Replacement(THR) is a surgical procedure that replaces a diseased hip joint with a prosthesis. A plastic or metal cup forms the socket, and the head of the femur is replaced by a metal ball on a stem placed inside the femur. Due to the various types and shapes of human hip joint of every individual, a selected commercial implant sometimes may not be the best-fit to a patient, or it cannot be applied because of its discrepancy. Hence extracting geometry parameters of hip joint is one of the most crucial processes in designing custom-made implants. This paper describes the framework of a methodology to extract the geometric parameters of the hip joint. The parameters include anatomical axis, femoral head, head offset length, femoral neck, neck shaft angle, anteversion, acetabulum, and canal flare index. The proposed system automatically recommends the size and shape of a custom-made hip implant with respect to the patient's individual anatomy from 3D models of hip structures. The proposed procedure creating these custom-made implants with some typical examples is precisely presented and discussed in this paper.

Keywords

References

  1. Kim, H. J., '관절염의 최신 수술 경향 : 고관절', 대한근관절건강학회지, Vol. 7, No. 2, pp. 367-368, 2000
  2. http://www.knia.or.kr/Medical/medibul/1999-vol5-1999_10/dan.htm
  3. http://most.news.go.kr/most/jsp/most1_branch.jsp?_action=news_view&_property=p_sec_1&_id=5006 1247&currPage =97&_category
  4. http://www.hss.edu/index.htm
  5. Blackwell, M., Simon, D., Rao, S. and DiGioia, A., 'Design and Evaluation of 3-D Pre-operative Planning Software: Application to Acetabular Implant Alignment', Tech report CMU-RI-TR- 96-44, Robotics Institute, Carnegie Mellon University, pp. 1-12, December, 1996
  6. Seel, M. J., Hafez, M. A., Eckman, K., Jaramaz, B., Davidson, D. and DiGioia III, A. M., 'Threedimensional Planning and Virtual Radiographs in Revision Total Hip Arthroplasty for Instability', Clinical Orthopaedics and Related Research, No. 442, pp. 35-38, 2006
  7. Amiot, L. and Poulin, F., 'Computed Tomography-Based Navigation for Hip, Knee, and Spine Surgery', Clinical Orthopaedics and Related Research, No. 421, pp. 77-86, 2004
  8. Wolf, A., DiGioia, A. M. III, Mor, A. B. and Jaramaz, B., 'Cup Alignment Error Model for Total Hip Athroplasty', Clinical Orthopaedics and Related Research, No. 437, pp. 132-137, 2005
  9. Walker, P. S., Blunn, G. W., Prada, D. and Casas, C., 'Design Rationale and Dimensional Considerations for a Femoral Neck Prosthesis', Clinical Orthopaedics and Related Research, No. 441, pp. 313-319, 2005 https://doi.org/10.1097/00003086-200512000-00047
  10. Wettstein, M., Mouhsine, E., Argenson, J., Rubin, P. J., Aubaniac, J. and Leyvraz, P., 'Three-dimensional Conputed Cementless Custom Femoral Stem in Young Patients', Clinical Orthopaedics and Related Research, No. 437, pp. 169-175, 2005
  11. Joskowicz, L. and Taylor, R. H., 'Preoperative Insertability Analysis and Visualization of Custom Hip Implants', Proc. of the 1st Int. Symposium on Medical Robotics and Computer Assisted Surgery, pp. 112-116, 1994
  12. Ahn, S. J., 'Least Squares Orthogonal Distance Fitting of Curves and Surfaces in Space', the Doctoral thesis, the University of Stuttgart, pp. 17-20, 2004
  13. Che, J. H., Yang, I. H. and Han, C. D., 'Radiographic Analysis of the Size and Shape of Proximal Femur', The Korean Hip Society, Vol. 17, No. 1, pp. 8-17, 2005
  14. Schneider, P. J. and Eberly, D. H., 'Geometric Tools for Computer Graphics', Morgan Kaufmann, pp. 534-539, 2003
  15. Thomas, S. M. and Chan, Y. T., 'A Simple Approach for the Estimation of Circular Arc Center and Its Radius', Computer Vision, Graphics, and Image Processing, Vol. 45, pp. 362-370, 1989 https://doi.org/10.1016/0734-189X(89)90088-1