In this paper, a new detection method of series arc-fault signals occurring at the wiring of home appliances is proposed. The discrete wavelet transform was used for the numerical analysis of the variation rate in peak, RMS, noise energy, shoulder of the arc-fault current wave. As a results, the arc distinction threshold value of these variation rates was about 0.1 in most cases. The arc-fault current of the loads with the active PFC circuit showed a high rate of variation in noise energy and shoulder, but arc-fault current of the loads without the active PFC circuit showed a high rate of variation in peak and RMS. The arc fault current in resistive loads showed a high rate of variation in shoulder.

키워드

참고문헌

  1. 산업자원부, "전기화재통계분석", 2007
  2. A.F. Sultan, G.W. Swift, D.J. Fedirchuk, "Detecting Arcing Downed-Wires Using Fault Current Flicker And Half-Cycle Asymmetry", IEEE Trans. on Power Delivery, Vol. 9, No. 1, Page(s) 461-470, Jan. 1994 https://doi.org/10.1109/61.277718
  3. C. Benner, P. Carswell, B.D. Russell, "Improved Algorithm For Detecting Arcing Faults Using Random Faults Behavior", Electric Power System Research, Vol. 17, pp. 49-56, 1989 https://doi.org/10.1016/0378-7796(89)90059-X
  4. S.J. Balser, K.A. Clements, D.J. Lawrence, "A Microprocessor-Based Technique For Detection of High Impedance Faults", IEEE Trans. on Power Delivery , Vol. PWRD-1, No. 3, Jul. 1986
  5. D.I. Jeerings, J.R. Linders, "Unique Aspects of Distribution System Harmonics Due to High Impedance Ground Faults", IEEE Trans. on Power Delivery, Vol. 5, No. 2, Apr. 1990
  6. B.D. Russell, R.P. Chinchali, C.J. Kim, "Behavior of Low Frequency Spectra During Arcing Fault And Switching Events", IEEE Trans. on Power Delivery, Vol. 3, No. 4, Oct. 1988
  7. B.D. Russell, R.P. Chinchali, "A Digital Signal Processing Algorithm For Detecting Arcing Faults on Power Distribution Feeders", IEEE Trans. on Power Delivery, Vol. 4, No. 1, Jan. 1989
  8. B.M. Aucoin, B.D. Russell, "Distribution High Impedance Fault Detection Utilizing High Frequency Current Components", IEEE Trans. on Power Apparatus and System, Vol. PAS-101, No. 6, Jun. 1982
  9. Wen-Jun Li, Yuan-Chun Li, "Arc Fault Detection based on Wavelet Packet", Proceedings of FICML, pp. 18-21, Aug., 2005
  10. W. Charytoniuk, W. J. Lee, M. S. Chen, J. Cultrera, T. Maffetone, "Arcing Fault Detection in Underground Distribution Networks Feasibility Study", Industry Applications, IEEE Transaction, Vol. 36, No. 6, pp. 1756-1761, Nov., 2000 https://doi.org/10.1109/28.887231
  11. A. Lazkano, J. Ruiz, E. Aramendi, L. A. Leturiondo, "Evaluation of A New proposal for Arcing Fault Detection Method Based on Wavelet Packet Analysis", Power Engineering Society Meeting, Vol. 3, pp. 1328-1333, July, 2001
  12. Nagy I. Elkalashy, Matti Lehtonen, Hatem A. Darwish, Mohamed A. lzzularab, Abdel Maksould I. Taalab, "Modeling and Experimental Verification of High Impedance Arcing Fault in Medium Voltage Networks", IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 14, No. 2, pp. 375-383, April, 2007 https://doi.org/10.1109/TDEI.2007.344617
  13. 방선배, 박종연, "웨이블렛 변환을 이용한 직렬 아크고장 신호 분석", 대한전기학회 논문지, Vol. 57, No. 3, pp. 494-500, Mar, 2008
  14. 기술표준원, "KS C 4613 누전차단기", 2002
  15. George D. Gregory, Kon Wong, Robert Dvorak, "More about Arc-Fault Circuit Interrupter", IEEE Transactions on Industry Applications, Vol. 40, No. 4, pp. 1006-1011, July/Aug., 2004 https://doi.org/10.1109/TIA.2004.831287
  16. George D. Gregory, Gary W. Scott, "The Arc-Fault Circuit Interrupter, An Emerging Product", Power Systems Technical Conference IEEE, pp. 48-55, May, 1998
  17. Underwrites Laboratories Inc. UL1699, "Arc-Fault Circuit-interrupters", May, 2003