참고문헌
- Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416 https://doi.org/10.1016/S0300-9785(81)80077-4
- Albrektsson T, Zarb G, Worthington P, Eriksson RA. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac implants 1986;1:11-25
- Jung YC, Han CH, Lee KW. A 1-year radiographic evaluation of marginal bone around dental implants. Int J Oral Maxillofac implants 1996;11:811-818
- Tarnow DP, Cho SC, Wallace SS. The effect of inter-implant distance on the height of inter-implant bone crest. J Periodontal 2000;71:546-549 https://doi.org/10.1902/jop.2000.71.4.546
- Grunder U, Gracis S, Capelli M. Influence of the 3-D bone-to-implant relationship on esthetics. Int J Periodontics Restorative Dent 2005;25:113-119
- Duyck J, Ronold HJ, Van Oosterwyck H et al. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study. Clin Oral Implants Res 2001;12:207-218 https://doi.org/10.1034/j.1600-0501.2001.012003207.x
- Quirynen M, Naert I, van Steenberghe D. Fixture design and overload influence marginal bone loss and fixture success in the Branemark system. Clin Oral Implants Res 1992;3:104-111 https://doi.org/10.1034/j.1600-0501.1992.030302.x
- Hermann JS, Cochran DL, Nummikoski PV, Buser D. Crestal bone changes around titanium implants. A radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandible. J Periodontol 1997;68:1117-1130 https://doi.org/10.1902/jop.1997.68.11.1117
- Hermann JS, Buser D, Schenk RK, Schoolfield JD, Cochran DL. Biologic width around one-and two-piece titanium implants. Clin Oral Implants Res 2001;12:559-571 https://doi.org/10.1034/j.1600-0501.2001.120603.x
- Piattelli A, Scarano A, Paolantonio M et al. Fluids and microbial penetration in the internal part of cement-retained versus screw-retained implant-abutment connections. J Periodontol 2001;72:1146-1150 https://doi.org/10.1902/jop.2000.72.9.1146
- Persson LG, Lekholm U, Leonhardt A, Dahlen G, Lindhe J. Bacterial colonization of internal surfaces of Branemark system implant components. Clin Oral Implants Res 1996;7:90-95 https://doi.org/10.1034/j.1600-0501.1996.070201.x
- Ericsson I, Rersson SG, Berglundh T, Marinello CP, Lindhe J, Klinge B. Different types of inflammatory reactions in periimplant soft tissue. J Clin Periodontol 1995;22:255-261 https://doi.org/10.1111/j.1600-051X.1995.tb00143.x
- Ericsson I, Nilner K, Klinge B, Glantz P-O. Radiographical and histological characteristics of submerged and nonsubmerged titanium implants. An experimental study in the Labrador dog. Clin Oral Implants Res 1996;7:20-26 https://doi.org/10.1034/j.1600-0501.1996.070103.x
- Abrahamsson I, Berglunch T, Linde J. Soft tissue response to plaque formation at different implant systems. A comparative study in the dog. Clin Oral Implants Res 1998;9:73-79 https://doi.org/10.1034/j.1600-0501.1998.090202.x
- Berglundh T, Lindhe J. Dimension of the periimplant mucosa. Biological width revisited. J Clin Periiodontol 1996;23:971-973 https://doi.org/10.1111/j.1600-051X.1996.tb00520.x
- Abrahamsson I, Berglundh T, Wennstrom J, Lindhe J. The peri-implant hard and soft tissue ant different implant systems. A comparative study in the dog. Clin Oral Implants Res 1996;7:212-219 https://doi.org/10.1034/j.1600-0501.1996.070303.x
- Weber HP, Buser D, Donath K et al. Comparison of healed tissues adjacent to submerged and non-submerged unloaded titanium dental implants. A histometric study in beagle dogs. Clin Oral Implants Res 1996;7:11-19 https://doi.org/10.1034/j.1600-0501.1996.070102.x
- Moon I-S, Berglundh T, Abrahamsson I, Linder E, Lindhe J. The barrier between the keratinized mucosa and the dental implant. An experimental study in the dog. J Clin Periodontol 1999;26:658-663 https://doi.org/10.1034/j.1600-051X.1999.261005.x
- Hermann JS, Buser D, Schenk RK, Higginbottom FL, Cochran DL. Biologic width around titanium implants. A physiologically formed and stable dimension over time. Clin Oral Implants Res 2000;11:1-11 https://doi.org/10.1034/j.1600-0501.2000.011001001.x
- Gardner DM. Platform switching as a means to achieving implant esthetics. A case study. N Y state Dent J 2005;71:34-37
- Lazzara RJ, Porter SS. Platform switching: A New concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restorative Dent 2006;26:9-17
- Todescan FF, Pustiglioni FE, Imbronito AV, Albrektsson T, Gioso M. Influence of the microgap in the peri-implant hard and soft tissues: A histomorphometric study in dogs. Int J Oral Maxillofac implants 2002;17:467-472
- Piattelli A, Scarano A, Piattelli M. Microscopical aspects of failure in osseointegrated dental implants: a report of five cases. Biomaterials 1996;17:1235-1241 https://doi.org/10.1016/0142-9612(96)84944-1
- Eriksson RA, Albrektsson T. The effect of heat on bone regeneration J Oral Maxillofac Surg 1984;42:701-711
- Wilderman MN, Wentz FM, Orban BJ. Histogenesis of repair after osseous surgery. J Periodontol 1970;41:551-565 https://doi.org/10.1902/jop.1970.41.10.551
- Gomez-Roman G. Influence of flap design on peri-implant interproximal crestal bone loss around single tooth implants. Int J Oral Maxillofac implants 2001;16:61-67