Abstract
Shear tests were carried out on interface between two concrete eco-blocks which comprise segmental retaining wall. Three interface conditions were considered : 1) direct contact of two blocks, 2) placing rubber pad between two blocks, 3) placing rubber pad and shear key between two blocks. According to shear tests, shear load-shear displacement relationship which was obtained from direct contact of two blocks was similar to elastic-perfectly plastic behavior. Ductile behavior of shear load-shear displacement relationship was observed for the interface condition of placing rubber pad. Apparent minimum shear capacities and apparent friction angles for the interface conditions of direct contact of two blocks, placing rubber pad between two blocks, placing rubber pad and shear key were 1.7 kN/m, $27.6^{\circ}$ and 4.2 kN/m, $26.2^{\circ}$ and 20.9 kN/m, $26.0^{\circ}$ respectively.
분리형부재 보강토 옹벽(SRW)을 구성하는 생태축조블록 접촉면에 대한 전단시험을 수행하였다. 전단이 발생하는 두 개의 블록 사이의 접촉면조건은 두 블록을 직접 접촉시키는 경우와 블록 사이에 고무패드를 설치한 경우 그리고 블록 사이에 고무패드와 전단키를 설치한 각각 3가지 접촉면 조건을 고려하였다. 전단시험에 따르면 두개의 블록을 직접 접촉시킨 경우 전단하중-전단변위 관계가 탄성-완전소성형태와 유사하였으며 블록 사이의 접촉면에 고무패드를 설치한 경우 전단하중-전단변위 관계는 연성거동을 보였다. 블록과 블록을 직접 접촉시킨 경우와 블록과 블록 사이의 접촉면에 고무패드를 설치한 경우 그리고 블록과 블록 접촉면 사이에 고무패드와 전단키를 설치한 경우에 대한 최소 전단저항력과 겉보기 마찰각은 각각 1.7kN/m, $27.6^{\circ}$와 4.2kN/m, $26.2^{\circ}$ 그리고 20.9kN/m, $26.0^{\circ}$이었다.