Accuracy Evaluation of Tidal Volume Measured on the Abdomen

복부에서 측정하는 일회 호흡용적의 정확도 평가

  • Published : 2008.07.01

Abstract

Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. This study implemented respiratory monitoring system with the conductive rubber cord in the patient's pants in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%$ $CO_2$ was inhaled and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation significantly increased the tidal volume in normal physiological state with the subject unawared. The tidal volume estimated from the abdominal dimension change linearly correlated with the tidal volume measured by a pneumotachometer with a correlation coefficient of 0.88. Customized calibration for each subject resulted in relative errors less than 10%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

Keywords

References

  1. A. C. Guyton, and J. E. Hall, Pulmonary ventilation, In: Textbook of medical physiology, Mansfield, H. I. E. Saunders, pp. 432-443, 2000
  2. 김경아, 김현식, 이태수, 차은종. 호흡기류를 동압력으로 변환하는 기능성 일회용 호흡관의 개발. 한국센서학회지, 제11권 3호, pp. 125-131, 2002. 5
  3. K. Konno, and J. Mead, 'Measurement of the separate volume changes of rib cage and abdomen during breathing', J. Appl. Physiol. Vol. 22, No. 3, pp. 407-422, 1967 https://doi.org/10.1152/jappl.1967.22.3.407
  4. Ambulatory Monitoring Inc., 'Respitrace systems', Instruction manual, 2004
  5. P. Bonato, 'Wearable sensors/systems and their impact on biomedical engineering', IEEE Engineering in medicine and biology magazine, Vol. 22, No. 3, pp. 18-20, 2003
  6. 김경아, 김성식, 조동욱, 이승직, 이태수, 차은종, '호흡 감지를 위한 복부 부착형 전도성 고무소자의 계측특성', 센서학회지 제 16권 제 1호, pp. 24-32, 2007 https://doi.org/10.5369/JSST.2007.16.1.024
  7. 이인광, 김성식, 장종찬, 김군진, 김경아, 이태수, 차은종. '지그비 통신 기반의 근거리 무선 호흡모니터 시스템'. 전기학회논문지 제 57권 제 1호, pp. 142-147, 2008
  8. F. S. Grodins, and S. M. Yamashiro, Control of Pulmunary Ventilation, In: Respiratory function of the lung and its control, Macmillan Publishing Co., Inc., New York, pp. 108-141, 1978
  9. A. Fleisch, 'Der pneumotachography: ein Apparatzur Beischwindgkeitregstrierung der Atemluft', Arch. Ges. Physiol. Vol. 209, pp. 713-722, 1925 https://doi.org/10.1007/BF01730956
  10. F. S. Grodins, and S. M. Yamashiro, Control of Pulmunary Ventilation, In: Respiratory function of the lung and its control, Macmillan Publishing Co., Inc., 1978, New York, pp. 46-85
  11. American Thoracic Society, 'Standardization of spirometry', Am. J. Respir. Crit. Care Med. Vol. 152, pp. 1107-1136, 1995 https://doi.org/10.1164/ajrccm.152.3.7663792
  12. 한국표준협회, '임상용 전자식 스파이로미터(KS P 1222)', In: 한국산업규격, 공업진흥청, 1989