A Novel Fault Detection Method using the PWM Characteristic at Open-Circuit Fault in NPC Inverter Systems

NPC 인버터 시스템에서 개방성 고장시 PWM 특성을 이용한 새로운 고장 검출 방법

  • 이정대 (한양대 공대 전기공학과) ;
  • 김태진 (한양대 공대 전기공학과) ;
  • 하동현 (한양대 공대 전기공학과) ;
  • 현동석 (한양대 공대 전기공학과)
  • Published : 2008.07.01

Abstract

In this paper, a novel fault detection method is proposed when the neutral-point-clamped inverter has a open-circuit fault in the switching device. This proposed method is configured with simple circuit and is achieved by a simple algorithm using the inherent characteristic of the continuous Pulse Width Modulation. Also, this method has the fast fault detection ability and is much simpler to embody, in comparison with conventional fault detection methods. This ability to detect fault minimizes harmful effect which are such as DC-link voltage unbalance and overstress to other switching devices. Therefore, this proposed fault detection method can improve reliability of NPC inverter system. Experimental results are presented to verify the validity of proposed fault detection method.

Keywords

References

  1. J. Rodrguez, J. S. Lai, and F. Z. Peng, 'Multilevel inverters: A survey of topologies, controls, and applications,' IEEE Trans. Ind. Electron., vol. 49, no. 4, pp. 724-738, Aug. 2002 https://doi.org/10.1109/TIE.2002.801052
  2. A. Bendre, G. Venkataramanan, D. Rosene, and V. Srinivasan, 'Modeling and design of a neutral-point voltage regulator for a three-level diode-clamped inverter using multiple-carrier modulation,' IEEE Trans. Ind. Electron.,vol. 53, no. 3, pp. 718-726, Jun. 2006 https://doi.org/10.1109/TIE.2006.874424
  3. J. Pou, J. Zaragoza, P. Rodrguez, S. Ceballos, V. M. Sala, R. P. Burgos, and D. Boroyevich, 'Fast-processing modulation strategy for the neutral-point-clamped converter with total elimination of low-frequency voltage oscillations in the neutral point,' IEEE Trans. Ind. Electron., vol. 54, no. 4, pp. 2288-2294, Aug. 2007 https://doi.org/10.1109/TIE.2007.894788
  4. D. Kastha, and B. K. Bose, 'Investigation of fault modes of voltage-fed inverter system for induction motor drive,' IEEE Trans. Ind. Appl., vol. 30, no. 4, pp. 1208-1038, Jul./Aug. 1994
  5. R. Spe and A. K. Wallace, 'Remedial strategy forbrushless dc drive failures,' IEEE Trans. Ind. Appl., vol. 26, no. 2, pp. 259-266, Mar./Apr. 1990 https://doi.org/10.1109/28.54251
  6. T. H. Liu, J. R. Fu, and T. A. Lipo, 'A strategy for improving reliability of field-oriented controlled induction motor drives,' IEEE Trans. Ind. Appl., vol. 29, pp. 910-918, Sep./Oct. 1993 https://doi.org/10.1109/28.245714
  7. G. T. Park, T. J. Kim, D.W. Kang, and D. S. Hyun, 'Control method of NPC inverter for continues operation under one phase fault condition,' in Conf. Rec. IEEE Industry Applications Society Annu. Meeting, Seattle, USA, pp. 2188-2193, 2004
  8. K. S. Smith, L. Ran, and J. Penman, 'Real-time detection of intermittent misfiring in a voltage-fed PWM inverter induction-motor drive,' IEEE Trans. Ind. Electron., vol. 44, no. 4, pp. 468-476, Aug. 1997 https://doi.org/10.1109/41.605620
  9. R. Peuget, S. Courtine, and J. P. Rognon, 'Fault detection and isolation on a PWM inverter by knowledge-based model,' IEEE Trans. Ind. Appl., vol. 34, no. 6, pp. 1318-1326, Nov./Dec. 1998 https://doi.org/10.1109/28.739017
  10. K. Rothenhagen and F. W. Fuchs, 'Performance of diagnosis methods for IGBT open circuit faults in three phase voltage source inverters for AC variable speed drives,' in Proc. 11th Eur. Conf. Power Electronics, EPE'05, Dresden, Germany, 2005, CD-ROM
  11. R. L. de Araujo Riberio, C. B. Jacobina, E. R. C. da Silva, and A. M. N. Lima, 'Fault detection of open-switch damage in voltage-fed PWM motor drive systems,' IEEE Trans. Power Electron., vol. 18, no. 2, pp. 587-593, Mar. 2003 https://doi.org/10.1109/TPEL.2003.809351