Performance Comparison of Liquid-Cooling with Air-Cooling Heat Exchangers Designed for Telecommunication Equipment

  • Jeon, Jong-Ug (Graduate School of Mechanical Engineering, Korea University) ;
  • Choi, Jong-Min (Department of Mechanical Engineering, Hanbat National University) ;
  • Heo, Jae-Hyeok (Graduate School of Mechanical Engineering, Korea University) ;
  • Kang, Hoon (Department of Mechanical Engineering, Korea University) ;
  • Kim, Yong-Chan (Department of Mechanical Engineering, Korea University)
  • 발행 : 2008.06.30

초록

Electronic and telecommunication industries are constantly striving towards miniaturization of electronic devices. Miniaturization of chips creates extra space on PCBs that can be populated with additional components, which decreases the heat transfer surface area and generates very high heat flux. Even though an air-cooling technology for telecommunication equipment has been developed in accordance with rapid growth in electrical industry, it is confronted with the limitation of cooling capacity due to the rapid increase of heat density. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, air-cooling heat exchangers were tested to provide performance data for the comparison with the liquid-cooling heat exchangers. The liquid-cooling heat exchangers had twelve rectangular channels with different flow paths of 1, 2, and 12. Silicon rubber heaters were used to control the heat load to the heat exchangers. Heat input ranged from 293 to 800W, and inlet temperatures of working fluid varied from 15 to $27^{\circ}C$. The heat transfer coefficients were strongly affected by flow conditions. All liquid-cooling heat exchangers showed higher cooling performance than the air-cooling heat exchanger. The heat exchanger with 2-paths could provide more controllability on the maximum temperature than the others.

키워드

참고문헌

  1. Mohamed, M., 2006, Air cooling characteristics of a uniform square modules array for electronic device heat sink, Applied Thermal Engineering, Vol. 26, pp. 486-493 https://doi.org/10.1016/j.applthermaleng.2005.07.013
  2. Sparrow, Y. O., 1984, Convective heat transfer response to height differences in an array of blocklike electronic components, Int. J. Heat and Mass Transfer, Vol. 27, pp. 469-473 https://doi.org/10.1016/0017-9310(84)90296-5
  3. Jang, Y. H., Kim, Y. C., 2005, An experimental study on the heat transfer and pressure drop in a mini-channel heat exchanger for electronic cooling, IIR-International Conference, Vicenza Italy, 31 Aug-2 Sept, pp. 591-598
  4. Li, P. C,, 2004, Three-dimensional analysis of heat transfer in a micro-heat sink with single phase flow, Int. J. Heat and Mass Transfer, Vol. 47, pp. 4215-4231 https://doi.org/10.1016/j.ijheatmasstransfer.2004.04.018
  5. Bhowmik, H. P., Tso, K. W., Tou, F. L., Tan, 2005. Convection heat transfer from discrete heat source in a liquid cooled rectangular channel, Applied Thermal Engineering, Vol. 25, pp. 2532-2542 https://doi.org/10.1016/j.applthermaleng.2004.11.022
  6. Lee, H., Jeong, Y., Shin, J., Kang, M., and Chun, K., 2004, Package embedded heat exchanger for stacked multi-chip module, Sensors and Actuators, A114, pp. 204-211
  7. Kim, S. J., Lee, S. W., 2000, Air cooling technology for electronic equipment, CRC Press. pp. 215-216
  8. Rousseau, P. G., Van Eldik, M., Greyvenstein, G. P., 2003, Detailed simulation of fluted tube water heating condensers, International Journal of Refrigeration, Vol. 26, pp. 232-239 https://doi.org/10.1016/S0140-7007(02)00077-4
  9. Jeon, J. U., Kim, Y. C., Choi, J. M. and Heo, J. H., 2005, Experimental study on the performance of an air-cooling system for telecommunication equipment, Proceedings of the SAREK, 2005-W-051, pp. 323-328
  10. Jeon, J. U., Kim, Y. C., Choi, J. M., 2006, Cooling performance of a hybrid refrigeration system for telecommunication equipment, Preceedings of the SAREK, 2006-S-077, pp. 489-494
  11. Jeon, J. U., Beak, C. H., Kim, Y. C. and Choi, J. M., 2006, Experimental study on the liquid cooling heat exchangers for the telecommunication equipment, Preceedings of the SAREK, 2006-W-033, pp. 192-197