Estimation of Systolic Blood Pressure using PTTL

PTTL을 이용한 수축기 혈압추정

  • 길세기 (인하대학교 전자공학과 정보전자공동연구소) ;
  • 권장우 (동명대학교 컴퓨터공학과) ;
  • 윤광섭 (인하대학교 전자공학과) ;
  • 이상민 (인하대학교 전자공학과)
  • Published : 2008.06.01

Abstract

The desirable method to diagnose abnormal blood pressure is to measure and manage blood pressure continuously and regularly. However, the sphygmomanometers that are based on a cuff have faults in that they can not measure the blood pressure continuously and they cause an unpleasant feeling. Therefore, it is essential to develop a new measuring method that causes no pain and that can obtain blood pressure continuously without any unpleasant feeling. Thus, we propose here a regression method to estimate the systolic blood pressure by using the PTTL(pulse transit time on leg) with some body parameters which are chosen from the relational analysis with systolic blood pressure. The data we use to make the regression model were obtained in triplicate from each of 50 males who were from 18 to 35 years. And we made estimation experiments of blood pressure on 10 males who did not take part in the making the regression model. According to the results, the proposed method showed a mean error of 4.00 mmHg and the standard variance was 2.45 mmHg. When we comparing the results of the proposed method with the rule of American National Standards Institute of the Association of the Advancement of Medical Instruments(ANSI/AAMI), the results satisfied the rule of a mean error less than 5 mmHg and a standard variance less than 8 mmHg. Therefore we were able to validate the usefulness of the proposed method.

Keywords

References

  1. K. W. Chan, K. Hung, Y.T. Zhang, "Noninvasive and cuffless measurements of blood pressure for telemedicine," IEEE Proceedings of EMBS International Conference, Vol 4, pp. 3592-3593, 2001
  2. L. J. Archer, A.J. Smith, "Blood pressure measurement in volunteers with and without padding between the cuff and the skin," Anaesthesia, Vol 56, pp. 847-849, 2001 https://doi.org/10.1046/j.1365-2044.2001.02180.x
  3. 정인철, "PPG를 이용한 심혈관 기능 및 혈압의 추정에 관한 연구," 공학석사학위청구논문, 연세대학교, 2005
  4. J. Lass, et al., "Continuous blood pressure monitoring during exercise using pulse wave transit time measurement", Proceedings of the 26th Annual International Conference of the IEEE EMBS, pp.2239-2242, 2004
  5. X. F. Teng and Y. T. Zhang, "Continuous and Noninvasive Estimation of ArterialBlood Pressure Using a Plethysmographic Approach", Proceedings of the 25th Annual International Conference of the IEEE EMBS, pp.3153-3156, 2003
  6. C. M. Lee and Y. T. Zhang, "Cufless and Noninvasive Estimation of Blood Pressure Based on a Wavelet Transform Approach", IEEE, pp.148-149, 2003
  7. E. K. Park et al, "A study on the estimation of continous blood pressure using PTT and biometric parameters," J. Biomed. Eng. Vol 27, pp1-6, 2006 https://doi.org/10.2220/biomedres.27.1
  8. 홍승길 편역, "인체 생리학," 제 1판, 고려의학, pp. 355-387, 1999
  9. 서광석 외, "상하지 광체적변동파형의 진폭과 맥파전도 시간을 이용한 지속적 동맥혈압 추정," Korean J Anesthesiol Vol 53, No. 2, pp159-168, 2007 https://doi.org/10.4097/kjae.2007.53.2.159
  10. Takazawa K, Tanaka N, Rujita M, Matsuoka O, Saiki T, Aikawa M, Tamura S, Ibukiyama C, "Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmograph waveform," Hypertension. 32, pp. 365-370, 1998 https://doi.org/10.1161/01.HYP.32.2.365
  11. Sandrine C Millasseau, Franck G. Guigui, Ronan P. Kelly, Krishna Prasad, John R. Cockcroft, James M. Ritter, Philip J. Chowienczyk, "Noninvasive Assessment of the Digital Volume pulse Comparison With the peripheral Pressure Pulse," Hypertension. 36, pp. 952-956, 2000 https://doi.org/10.1161/01.HYP.36.6.952
  12. 양완연, "일반통계학," 연학사, pp. 301-336, 2001
  13. 노형진, "SPSS 10.0에 의한 조사방법 및 통계분석," 형설 출판사, pp.317-358, 2001