DOI QR코드

DOI QR Code

세균 Pseudomonas sp. YK-32 균주에 의한 Formaldehyde 분해 최적조건

Optimum Conditions of Formaldehyde Degradation by the Bacterium Pseudomonas sp. YK-32

  • Kim, Young-Mog (Department of Food Science & Technology, Pukyong National University) ;
  • Lee, Yun-Kyoung (Department of Food Science & Technology, Pukyong National University) ;
  • Kim, Kyoung-Lan (Department of Mocrobiology, Pukyong National University) ;
  • Lee, Eun-Woo (Department of Life Biotechnology, Dongeui University) ;
  • Lee, Myung-Suk (Department of Mocrobiology, Pukyong National University)
  • 발행 : 2008.04.30

초록

Formaldehyde, an indoor volatile organic compound, is considered toxic due to its carcinogenic risk. Recently, we isolated a formaldehyde-degrading bacterium Pseudomonas sp. YK-32. A crude enzyme prepared from YK-32 also degraded formaldehyde, suggesting that YK-32 cells have formaldehyde hydrogenase activity which is one of the important factors in formaldehyde degradation. The formaldehyde hydrogenase activity was increased 1.25 fold by adding 0.1 % glucose and formaldehyde to the culture medium. In addition, treatment with 1 mM EDTA as a permeabilizer promoted the degradation of formaldehyde and increased the enzymatic activity.

키워드

참고문헌

  1. Bradford, M.M. 1976. A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding. Anal. Biochem., 72, 248-254 https://doi.org/10.1016/0003-2697(76)90527-3
  2. Choi, J.H., T.K. Kim, Y.M. Kim, W.C. Kim, K. Park and I.K. Rhee. 2006. Cloning and characterization of a gene cluster for cyclohexanoneol oxidation in Rhodococcus sp. TK6. J. Microbiol. Biotechnol., 16, 511-518
  3. Dorsev, C.W. and L.A. Actis. 2003. Analysis of pVU3695, a plasmid encoding glutathione-dependent formalde- hyde dehydrogenase activity and formaldehyde resistance in the Escherichia coli VU3695 clinical strain. Plasmid, 51, 116-126 https://doi.org/10.1016/j.plasmid.2003.12.001
  4. Ha, K.C. 2004. Characteristics of formaldehyde con- centrations in the underground spaces in Gyungnam Province. Kor. J. Environ. Health, 30, 353-375
  5. Jeon, B.K., K.C. Choi and J.M. Suh. 2006. Development for UV/$TiO_2$ photocatalytic oxidation indoor air compound process. J. Environ. Sci., 15, 855-864 https://doi.org/10.5322/JES.2006.15.9.855
  6. Kim, Y.M., K. Park, G.J. Joo, E.M. Jeong, J.E. Kim and I.K. Rhee. 2004. Glutathione-dependent biotrans- formation of the fungicide chlorothalonil. J. Agric. Food Chem., 52, 4192-4196 https://doi.org/10.1021/jf040047u
  7. Kim, Y.M., K. Park, G.J. Joo, E.M. Jeong, J.E. Kim and I.K. Rhee. 2007. Cloning and characterization of a catechol-degrading gene cluster from 3,4-dichloro- aniline degrading bacterium Pseudomonas sp. KB35B. J. Agric. Food Chem., 55, 4722-4727 https://doi.org/10.1021/jf070116f
  8. Kim, Y.S., J.D. Lee, C.M. Lee, S.W. Yoon and Y.S. Choi. 2000. A study air pollution in indoor gymnasiums. Kor. J. Environ. Health Soc., 26, 3, 32-37 https://doi.org/10.5271/sjweh.507
  9. Lee, S.I. 1997. A study on airborne concentration of formaldehyde in underground environments in Taegu city. J. Kor. Soc. Environ. Admin., 3, 49-66
  10. Obee, T.N. and R.T. Brown. 1995. $TiO_2$ phtocatalysis for indoor air applicaton, effect of humidity and trace contaminants levels on the oxidation rate of formaldehyde, roluene and 1,3-butadiene. J. Environ. Technol., 29, 5-9
  11. Pawel, W., D.P. Wyon, Y.K. Baik, G. Clausen and P.O. Finger. 1999. Perceived air quality, sick building syndrome (SBS) symptoms and productivity in an office with two different pollution loads. Indoor Air, 9, 165-179 https://doi.org/10.1111/j.1600-0668.1999.t01-1-00003.x
  12. Schoenberg, J.B. and C.A. Mitchell. 1975. Airway disease caused by phenolics (phenol-formaldehyde) resin exposure. Arch. Environ. Health, 30, 572-577
  13. Shim, S.H. and Y.S. Kim. 2006. Characterization and assessment of indoor air quality in newly constructed apartments-volatile organic compounds and for- maldehyde. Kor. J. Environ. Health, 32, 275-281
  14. Tepper, J.S., V.C. Moser, D.L. Costa and M.A. Mason. 1995. Toxicological and chemical evaluation of emission from carpet samples. Am. Ind. Hyg. Assoc., 52, 158-170
  15. Tobin, R.S., M. Bourgeau, R. Otson and G.C. Wood. 1992. Residential indoor air quality guidelines. Indoor Environ., 2, 267-275 https://doi.org/10.1177/1420326X9300200503