In this study, we had the stress analyses of TBP used in Tall Building and determined the working pressure of TBP. We knew the four fact. First, the place acted maximum stress is axial direction of branched part. Second, working pressure is more than 2.0 MPa. Third, stress in branched part is less than yielding strength at hydrostatic test pressure. Fourth, the ratio(stress/yielding stress at hydrostatic test pressure) is $0.4{\sim}0.6$(KS D 3562 Sch 40), $0.3{\sim}0.4$(KS D 3576 20S).

Keywords

References

  1. KFI Corp. 2006, KFI Certificated Standard of T-Branched Pipe, p. 1
  2. Nam, J. S., et al., 2007, A study on the Strength Analyses of T-branch Pipes, T. of Korean Institute of Fire Sci. and Eng., Vol. 21, No. 2, p. 36
  3. UL, 2004, Alarm Valves for Fire-Protection Service, UL 193, 28. Strength of body test, p. 22
  4. FM, 2004, Approval Standard for Deluge Systems and Preaction Systems, FM Class Number 1011 and 1012, 7.3 Hydrostatic Tests, p. 8
  5. FM, 2004, "Approval Standard for Dry Pipe Valves", FM Class Number 1021, 4.5 Hydrostatic Tests, p. 6
  6. KS D 3562, 1989, Carbon Steel Pipes for Pressure Service, KS CODE, Attachment, Vol. 1. p. 6
  7. KS D 3576, 2003, Stainless steel pipes, KS CODE, Attachment, Vol. 1-1, p. 10