Assessment of Daylight Environment on Light Pipe System Under Different Solar Position

태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가

  • Shin, Hwa-Young (Dept. of Architectural Engineering, Graduate School, Kyung Hee University) ;
  • Kim, Jeong-Tai (Dept. of Architectural Engineering, Kyung Hee University)
  • Published : 2008.12.30

Abstract

The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

Keywords

References

  1. 윤현주, "건축과 자연채광 시스템", 삼성건 설기술 친환경에너지팀, pp.56-59, 2008.6
  2. L SHAO, S B RIFFAT, W HICKS, I YO HANNES, "A Study of Performance of Light Pipes Under Cloudy and Sunny Co ndition in the UK", The 4th European C oference on Energy-Efficient Lighting, D enmark, 1997
  3. L. Shao, S B Riffat, I Yohannes, A.A El mualim, "measurement and modelling of light pipe for energy efficient lighting", CIBSE National Lighting Conference Pa per, 1998
  4. G. OAKLEY, S. B. RIFFAT, L. SHAO, " Daylight Performance of Lightpipes", Sol ar Energy, Vol.69, No.2, pp.89-98, 2000 https://doi.org/10.1016/S0038-092X(00)00049-9
  5. M. paronicini, B. Calcagni, F. Corvaro, " Monitoring of a light-pipe system", Solar Energy 81, pp.1180-1186, 2007 https://doi.org/10.1016/j.solener.2007.02.003
  6. 김정태, 정유근, 김선국 외, "광파이프 시 스템의 채광성능 평가", 대한건축학회 논 문집, 제17권, 제4호, pp.119-124, 2001.04
  7. 신혜미, 박훈, 김정태, "수직형 라이트파이 프의 채광성능에 관한 예비평가", 한국생태 환경건축학회 논문집, pp.119-124, 2008.02
  8. Laouadi,A."Design Insights on Tubular Skylights", Lighting V.25, No.1, pp.38-41, 2005.02
  9. KS핸드북 2005 조명, KSA 한국표준협회