A Study on the Detecting Accuracy of EM Induction Survey Data of Buried Utility

전자유도 탐사를 이용한 지하매설물 탐지 정확도 분석

  • 권형석 (삼성물산(주) 건설부문 기술연구소) ;
  • 최준호 (삼성물산(주) 건설부문 기술연구소) ;
  • 황대진 (삼성물산(주) 건설부문 기술연구소) ;
  • 김문재 (삼성물산(주) 건설부문 수인선4공구) ;
  • 윤정섭 (삼성물산(주) 건설부문 수인선4공구)
  • Received : 2008.10.09
  • Accepted : 2008.11.18
  • Published : 2008.12.31

Abstract

Electromagnetic induction surveys are one of the useful methods to detect the location and buried depth of underground utilities by measuring horizontal and vertical magnetic fields. It can effectively detects single buried utility with the accuracy of within 20 cm. However when another utility is buried near to target one, the accuracy of utility location considerably decreases due to the distortion of magnetic fields caused from adjacent utility. This study shows the ways to verify the location and buried depth of target utility when magnetic fields does not show symmetric distribution due to adjacent another utility. Using Bluetooth wireless communication tools, we developed the way to records measured magnetic fields to handheld PDA. We investigated the criteria for minimum distance of two adjacent utilities to separate the individual responses through field model test.

전자유도 탐사는 매설관로에서 발생되는 자기장을 측정하는 탐사방법으로 하나의 관로만 매설되어 있는 경우에는 20 cm 이내의 높은 정확도를 보이지만, 탐지대상 관로 인근에 다른 관로가 매설되어 있으면 자기장의 교란으로 정확도가 감소한다. 본 연구에서는 지하매설물 탐지 정확도 향상을 위하여 대칭성을 이용하여 매설관로의 수평위치를 검증하는 방법과 에너지 크기 비교법과 삼각법을 이용하여 매설심도를 검증하는 방법에 대해 고찰하였다. 다음으로 현재 판매되는 전자유도 탐사장비가 별도의 저장장치를 가지고 있지 않아 측정자료의 분석이 불가능한 문제를 개선하기 위하여, Bluetooth 무선통신장치를 이용하여 측정자료를 저장하는 방법을 개발하였다. 마지막으로 두 개의 인접관로를 하나로 오인하는 문제점을 개선하기 위하여 현장모형실험을 통해 인접관로의 거리에 따른 분해능을 고찰하였다.