An experimental study of the time based mass flow controller for semiconductor industry
반도체용 시간식 질량유량계의 특성에 관한 연구
- Chang, Young-Chul (School of Mechatronics Engineering, Korea University of Technology and Education)
- 장영철 (한국기술교육대학교 메카트로닉스공학부)
- Published : 2008.06.30
Abstract
The objective of the research is to design, manufacture and test a Mass Flow Controller(MFC) capable of measuring compressible fluid flows based on a "bucket and stop-watch"method. The basic principle is the measurement of time, where the time taken to fill and empty a bucket of known volume is measured. This method of flow measurement is a new concept when compared to a commercilized current mass flow controller. For the flow meter to be able to compete with established designs it not only must be comparable in cost and robustness, it must be very accurate and reliable as well. This device should be able to handle fluid flows in the range of 0.1ml/min to 10ml/min within an accuracy of