DOI QR코드

DOI QR Code

Flexural strength of high-strength concrete filled steel tube columns strengthened by carbon fiber sheets

탄소섬유쉬트로 보강한 고강도 콘크리트 충전강관(CFT) 기둥의 휨내력에 관한 연구

  • Published : 2008.02.29

Abstract

The CFT (Concrete Filled Steel Tube) columns became popular in high rise building construction due to not only its composite effect but also economic advantage. However, it has been pointed out in various previous researches that the current practice in CFT columns may lead the steel tube to probable local buckling at critical sections of the columns right after yielding. To resolve such a problem, the TR-CFT (Transversely Reinforced Concrete Filled Steel Tube) column is proposed to control or at least delay the local buckling state at the critical section by wrapping the CFT columns with carbon fiber sheet. The validity of the proposed column system is validated through the present paper by observing the experimental performance and comparing it with the analytical prediction of the TR-CFT columns with hish strength concrete. It is also shown that the current design code provisions such as ACI-318, in which the contribution of concrete confining effect filled in steel tube is not appropriately accounted for, may contain too much conservatism.

CFT(Concrete Filled Steel Tube)기둥은 부재의 합성효과와 경제적인 측면 때문에 최근 고층건물 시공 시 널리 쓰이고 있다. 그러나 기존의 연구문헌을 살펴보면 CFT 기둥은 강관의 항복이후 강관의 일정지점에 국부좌굴이 생기는 단점을 지니고 있다. 이러한 문제점을 해결하기 위하여 예상 국부좌굴부위를 탄소섬유쉬트로 보강하여 국부좌굴을 방지하거나 지연시키는 TR-CFT (Transversely Reinforced Concrete Filled Steel Tube) 기둥에 관한 연구가 진행되고 있다. 본 연구에서는 고강도 콘크리트를 사용한 TR-CFT기둥의 실험을 수행하였으며 휨내력에 대한 해석을 수행한 결과 실험값과 해석값이 잘 일치하였다. 또한 기존의 ACI 318 설계법은 강관내부에서 발생하는 콘크리트에 대한 구속효과를 고려하지 않아 저평가가 되어있음을 알 수 있었다.

Keywords

References

  1. 최성모, 강석빈, 김대중, "저축력과 반복수평력을 받는 콘크리트충전 강관기둥의이력특성", 한국강구조학회논문집, 제 15권 2호, 2003, pp. 207-217
  2. 박재우, 김진호, 홍영균, 홍기섭, "축력과 반복수평력을 받는 TR-CFT기둥에 관한 실험적 연구", 한국강구조학회 논문집, 제 19권 4호, 2007, pp. 403-412
  3. Y. Xiao., W. He., K. K. Choi., "Confined Concrete-Filled Tubular Columns", Journal of Structural Engineering, ASCE, Vol. 131, No. 3, 2005, pp. 488-497 https://doi.org/10.1061/(ASCE)0733-9445(2005)131:3(488)
  4. ACI Committee 318., "Building Code Requirements for Structural Concrete and Commentary," American Concrete Institute., pp.119-122
  5. J. B. Mander., M. J. N. Priestley., R. Park., "Theoretical Stress-Strain Model for Confined Concrete", Journal of Structural Engineering, ASCE, Vol. 114, No. 8, 1988, pp. 1804-1826 https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804)
  6. S. Popovics., "A Numerical Approach to the Complete Stress-Strain Curve for Concrete", Cement and Concrete Research, Vol. 3, No. 5, 1973, pp. 583-599 https://doi.org/10.1016/0008-8846(73)90096-3
  7. M. R. Spoelstra., G. Monti., "FRP-Confined Concrete Model", Journal of Composites and Construction, ASCE, Vol. 3, No. 3, 1999, pp. 143-150 https://doi.org/10.1061/(ASCE)1090-0268(1999)3:3(143)
  8. S. J. Pantazopoulou., R. H. Mills., "Microstructural Aspects of the Mechanical Response of Plain Concrete," ACI Materials Journals, Vol. 92, No. 6, 1995, pp. 605-616
  9. Y. C. Wang., J. I. Restrepo., "Investigation of Concentrically Loaded Reinforced Concrete Columns Confined with Glass Fiber-Reinforced Polymer Jackets," ACI Structural Journals, Vol. 98, No. 3, 2001, pp. 377-385
  10. ANSI/ AISC 341-02, "Seismic Provisions for Structural Steel Buildings", pp. 40-41
  11. M. J. N. Priestley., F. Seible., G., M. Calvi., "Seismic Design and Retrofit of Bridges," John Wiley & Son, INC., 1992, pp. 377-385
  12. J. G. Teng., J. F. Chen., S. T. Smith., L. Lam., "FRP Strengthened RC Structures", John Wiley & Son, INC., 2002, pp. 168-176
  13. J. G. Macgregor., "Reinforced Concrete Mechanics and Design", Prentice Hall, INC., 1997, pp. 429-441