Reccurent Foreign body Granuloma after Gore-tex Removal in Rhinoplasty

융비술에서 고어텍스 제거 후 발생한 재발성 이물성 육아종의 치험례

  • Kwon, Soon Geun (Department of Plastic and Reconstructive Surgery, College of Medicine, Kyung Hee University) ;
  • You, Young Cheun (Art Plastic Surgery Clinic) ;
  • Yang, Won Yong (Department of Plastic and Reconstructive Surgery, College of Medicine, Kyung Hee University) ;
  • Park, Jun (Starline Plastic Surgery Clinic) ;
  • Kang, Sang Yun (Department of Plastic and Reconstructive Surgery, College of Medicine, Kyung Hee University)
  • 권순근 (경희대학교 의과대학 성형외과학교실) ;
  • 유영천 (아트 성형외과) ;
  • 양원용 (경희대학교 의과대학 성형외과학교실) ;
  • 박준 (스타라인 성형외과) ;
  • 강상윤 (경희대학교 의과대학 성형외과학교실)
  • Received : 2008.04.04
  • Accepted : 2008.07.28
  • Published : 2008.10.15

Abstract

Purpose: Infection, foreign body reaction and decreased volume of implant are common complications after augmentation rhinoplasty with $Gore-tex^{(R)}$ implant. The author experienced two cases of recurrent foreign body granuloma in the patients who underwent $Gore-tex^{(R)}$ removal because of infection after augmentation rhinoplasty. and treated them with complete removal of$Gore-tex^{(R)}$. Methods: Case 1: A 49 year-old female visited our clinic for recurrent foreign body reaction on nasal dorsum and tip area. The patient underwent augmentation rhinoplasty with $Gore-tex^{(R)}$ 3 years ago and implant was removed due to infection 9 months ago. Excision of the granuloma was performed and a piece of foreign body suspicious to be a $Gore-tex^{(R)}$ implant debris was detected under the subcutaneous pocket. The implant fragments were removed and nasalis muscle rotation flap was performed to cover the lesion. The specimen was proved to be $Gore-tex^{(R)}$ in histological study. Case 2: A 31 year-old-male with recurrent foreign body granuloma on the nasal tip area visited our clinic. 10 years ago, the patient had augmentation rhinoplasty with silicone implant and then, he underwent revisional rhinoplasty five times including nasal implant removal, which was performed 9 months ago. The authors excised the granuloma and found a small sized foreign body suspicious to be a $Gore-tex^{(R)}$ implant debris under the granuloma. The foreign body was excised and identified to be $Gore-tex^{(R)}$ in histological study. Results: In both cases, the lesions were healed without any complications and there were no evidences of recurrence up to 6 months of follow-up. Conclusion: The $Gore-tex^{(R)}$ is known to be weak against mechanical force. These properties of $Gore-tex^{(R)}$ make it difficult to remove the implant completely. In the patient who have infection after augmentation rhinoplasty with $Gore-tex^{(R)}$, the operator should take care to perform the complete removal without remaining fragment of the implant.

Keywords

References

  1. Conrad K, Gillman G: A 6-year experience with Gore- tex$^{\circledR}$ in rhinoplasty. Plast Reconstr Surg 101: 1675, 1998 https://doi.org/10.1097/00006534-199805000-00040
  2. Godin MS, Waldman SR, Johnson CM: Nasal augmentation using Gore-tex$^{\circledR}$: a 10 year experience. Arch Facial Plast Surg 1: 118, 1999 https://doi.org/10.1001/archfaci.1.2.118
  3. Yoo YC, Chung SI, Yang WY, Ko BM: Experience with use of expanded polytetrafluoroethylene(Gore-tex$^{\circledR}$) in cosmetic facial surgery. J Korean Soc Plast Reconstr Surg 30: 7, 2003
  4. Jin HR, Lee JY, Yeon JY, Rhee CS: Multicenter evaluation of the safety of Gore-tex$^{\circledR}$ as an implant in Asian rhinoplasty. Am J Rhinol 20: 615, 2006 https://doi.org/10.2500/ajr.2006.20.2948
  5. Lohuis P, Watts SJ, Vuyk HD: Augmentation of the nasal dorsum using: intermediate results of a retrospective analysis of experience in 66 patients. Clin Otolaryngol 26: 214, 2001 https://doi.org/10.1046/j.1365-2273.2001.00453.x
  6. Merritt K, Shafer JW, Brown SA: Implant site infection rates with porous and dense materials. J Biomed Mater Res 13: 101, 1979 https://doi.org/10.1002/jbm.820130111
  7. Mendelsohn M, Dunlop G: Gore-tex$^{\circledR}$ augmentation grafting in rhinoplasty-is it safe? J Otolaryngol 27: 337, 1998
  8. Schoenrock LD, Repucci AD: Correction of subcutaneous facial defects using Gore-tex$^{\circledR}$. Facial Plast Surg Clin North Am 2: 373, 1994