Abstract
This study aims at an assessment of the effectiveness of taste & odor removal and transmembrane pressure changes in a pilot membrane plant(500m3/day) by adding PAC to MF process, and at providing a basis for applying it to the advanced water treatment process. The transmembrane pressure showed, in low turbidity of raw water, a tendency to decrease when PAC was injected at the Flux of 1, $1.5m^3/m^2{\cdot}d$, while it increased in high Flux($1.5m^3/m^2{\cdot}d$) in high turbidity of raw water. in addtion, it is shown that the fouling could be reduced more when PAC is injected together with appropriate amount of coagulant, than when PAC is solely injected. Taste & Odor-causing 2-MIB may not be detected in membrane filtered water, if the amount of PAC injection is increased in accordance with the increasing concentration of 2-MIB. Hence, PAC injection, as a pre-treatment process in MF membrane filtering, is supposed to be a suitable process for reducing fouling as well as for improvement effectiveness of taste & odor treatment.