Wooden Foreign Body in the Parotid Gland

이하선 목재 이물

  • Moon, Yoo Jin (Department of Plastic and Reconstructive Surgery, College of Medicine, Soonchunhyang University) ;
  • Choi, Hwan Jun (Department of Plastic and Reconstructive Surgery, College of Medicine, Soonchunhyang University) ;
  • Kim, Mi Sun (Department of Plastic and Reconstructive Surgery, College of Medicine, Soonchunhyang University) ;
  • Choi, Chang Yong (Department of Plastic and Reconstructive Surgery, College of Medicine, Soonchunhyang University) ;
  • Park, Jin Gue (Department of Otolaryngology, College of Medicine, Soonchunhyang University) ;
  • Kim, Jun Hyuk (Department of Plastic and Reconstructive Surgery, College of Medicine, Soonchunhyang University)
  • 문유진 (순천향대학교 의과대학 성형외과학교실) ;
  • 최환준 (순천향대학교 의과대학 성형외과학교실) ;
  • 김미선 (순천향대학교 의과대학 성형외과학교실) ;
  • 최창용 (순천향대학교 의과대학 성형외과학교실) ;
  • 박진규 (순천향대학교 의과대학 이비인후과학교실) ;
  • 김준혁 (순천향대학교 의과대학 성형외과학교실)
  • Received : 2007.11.23
  • Published : 2008.03.10

Abstract

Purpose: Now the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma on the face is often underestimated in physical examination. Wood, with its porous consistency and organic nature, provides a good medium for microbial agents. This is a report of our recent experience with wooden foreign bodies in the parotid gland imaged with CT. Methods: A 9-year-old boy was referred for evaluation of possible retained foreign body within his face. One day earlier, he had fallen, face down approximately 1 miter onto ground. He had subsequently undergone an exploration of his right parotido-masseteric area at an outside hospital with repair of a right facial laceration. Enhanced 2 mm axial and coronal CT scans were obtained through the face. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2 mm section thickness. Results: We finally decided the linear "gas" attenuation was a foreign body because of its linear configuration, which did not conform to that of an anatomic structure, and on the basis of articles that described a wood foreign body in the orbit as having the appearance of air. We found that wood was hypoattenuating($-464{\pm}27HU$). Conclusion: We recommend this type of software program for CT scanning for any patient with an injury on the face in which a foreign body is suspected.

Keywords

References

  1. Lim SJ, Lee JB, Hong YJ: A case of intraorbital foreign body. J Korean Ophthalmol Soc 26: 123, 1985
  2. Jeong SH, Shin SH, Park SH, Koo SH: Measurement analytical study of computed tomography of the orbital structure in acute blow-out fracture. J Korean Soc Plast Reconstr Surg 34: 44, 2007
  3. Paik HW, Choi JW, Chong HK, Lee PK, Ahn ST: Clinical experience of foreign body granuloma in the apex of orbit. J Korean Soc Plast Reconstr Surg 32: 131, 2005
  4. Kim SH, Byeon JH, Rhie JW, Lim P: 2 Cases of penetrating intraorbital injury and complication caused by wood. J Korean Soc Plast Reconstr Surg 23: 833, 1996
  5. Zinreich SJ, Miller NR, Aguayo JB, Quinn C, Hadfield R, Rosenbaum AE: Computed tomographic three-dimensional localization and compositional evaluation of intraocular and orbital foreign bodies. Arch Ophthalmol 104: 1477, 1986 https://doi.org/10.1001/archopht.1986.01050220071029
  6. Roberts CF, Leehey PJ 3rd: Intraorbital wood foreign body mimicking air at CT. Radiology 185: 507, 1992 https://doi.org/10.1148/radiology.185.2.1410363
  7. McGuckin JF Jr, Akhtar N, Ho VT, Smergel EM, Kubacki EJ, Villafana T: CT and MR evaluation of a wooden foreign body in an in vitro model of the orbit. AJNR Am J Neuroradiol 17: 129, 1996
  8. Etherington RJ, Hourihan MD: Localization of intraocular and intraorbital foreign bodies using computed tomography. Clin Radiol 40: 610, 1989 https://doi.org/10.1016/S0009-9260(89)80320-4