Acknowledgement
Supported by : Changwon National University
References
- ACGIH. American Conference of Governmental Industrial Hygienists. Industrial Ventilation -A Manual of Recommended Practice (25th ed.) ISBN 1-882417-52-6.; 2004
- Battista WP. Semi-lateral tank ventilation hood controls contaminant, cut costs. Heat. Piping Air Condition. v.19. 1947: 85-89
- Chen Q. : Comparison of different k-e models for indoor airflow computation. Numerical Heat Transfer, Part B, Fundamentals, v.28. 1995: 353-369 https://doi.org/10.1080/10407799508928838
- Chen Q. : Simplified diffuser boundary conditions for numerical room airflow models. Repor ASHRAE 1791 Tullie Circle, NE Atlanta.2001: 30329-2305
- Chern and Ma Chen-Hsuan : Numerical investigation and recommendations for push-pull ventilation systems. Journal of Occupational and Environmental Hygiene, v.4.2007: 184?197
- Conroy LM. et al, : An analytical, numerical, and experimental comparison of the fluid velocity in the vicinity of an open tank with one and two lateral exhaust slot hoods and a uniform crossdraft. Ann. Occup. Hyg., Vol. 44, No. 6, 2000: pp. 407- 419 https://doi.org/10.1016/S0003-4878(99)00111-8
- Ega and Silverman L. : Design of push-pull exhaust systems.Heat Ventil. v.10.1950: 73-78
- Flynn MR. et al : Three dimensional finite-element simulation of a turbulent push-pull ventilation system. Ann Occup Hyg; 39.1995: 573-589 https://doi.org/10.1016/0003-4878(95)00029-E
- Hama GM. : Supply and exhaust ventilation for metal picking operations. Air Cond. Heat Ventil.54.1957: 61-63
- Hughes RT. and Huebener, D.J. : Development of push-pull ventilation criteria. Division of Physical Sciences and Engineering, National Institute for Occupational Safety and Health, Cincinnati, Ohio.1982
- Huebener DJ. and Hughes R.T. : Development of push-pull ventilation. Am.ind.Hyg.AssJ.46. 1985:262-267 https://doi.org/10.1080/15298668591394789
- Kulmala Ilpo. : Numerical simulation of a local ventilation unit. Ann.Occup.Hyg., Vol.38, No.4, 1994:pp.337-349
- Kulmala Ilpo. : Numerical calculation of the capture efficiency of an unflanged circular exhaust opening. Ventilation 94, Proceedings of the 4thInternational Symposium on Ventilationfor Contaminant Control. Solna: Arbete och18.1994:.pp.339-334
- Loomans. M. : The measurement and simulation of indoor air flow. Ph.D. Dissertation, Eindhoven University of Technology, the Netherlands.1998
- Malin BS. : Practical pointers on industrial exhaust system. Heat Ventil. 42. 1945: 75- 82
- Marzal F. et al. : Methodologies for determining capture efficiencies in surfacetreatment tanks. AIHA Journal 64.2003:604-608 https://doi.org/10.1080/15428110308984852
- Marzal F. et al. : Determination and interpretation of total and transversal linear efficiencies in push-pull ventilation systems for open surface tanks. Ann. Occup. Hyg. Vol. 46, No. 7,2002: pp. 629-635 https://doi.org/10.1093/annhyg/mef078
- Robinson M. and Ingham DB.: Recommendations for the design of push-pull ventilation systems for open surface tank. Ann.occup.Hyg.,Vol.40, No.6,1996a: pp.693-704 https://doi.org/10.1016/S0003-4878(96)00011-7
- Robinson M and Ingham DB. . Numerical modeling of the flow patterns induced by a push-pull ventilation system. Ann Occup Hyg; Vol.40, No.6, 1996b: pp. 293?310
- Robinson,M, and Ingham DB. : Design and operating parameters for push-pull ventilation of open surface tanks. Int.J.Energy Res. 27. 2003: 757-770 https://doi.org/10.1002/er.914
- Rota R. et al. : Design guidelines for push-pull ventilation systems through computational fluid dynamics modeling. AIHAJ.62,2001:141-148 https://doi.org/10.1080/15298660108984616
- Song Se-Wook .et al : Evaluation of capture efficiencies of push-pull hood systems by crossdraft directions and velocities using smoking visualization technique. Korean Soc Occup Environ Hyg 15(1). 2005 ::36-44
- Song Se-Wook. : The evaluation of capture efficiencies of push-pull ventilation systems under crossdraft Ph.D.Dissertation, Department of Environmental Engineering, Changwon National University, Korea.2005