참고문헌
- Hasegawa, B. H., 'The Physics of Medical X-ray Imaging, Madison, Wisconsin,' Medical Physics Publishing Company, 1991
- Cunningham, I. A., 'Applied Linear-Systems Theory,' Chapter 2, Handbook of Medical Imaging: Vol. 1. Physics and Psychophysics (Eds. J. Beutel, H.L. Kundel, and R. Van Metter), SPIE, 2000
- Dobbins III, J. T., 'Image Quality Metrics for Digital Systems,' Chapter 3, Handbook of Medical Imaging: Vol. 1. Physics and Psychophysics (Eds. J. Beutel, H.L. Kundel, and R. Van Metter), SPIE, 2000
- Rose, A., 'The Sensitivity Performance of The Human Eye on The Absolute Scale,' J. Opt. Soc. Am., Vol. 38, No. 2, pp. 196-208, 1948 https://doi.org/10.1364/JOSA.38.000196
- Moy, J. P., 'Signal-to-Noise Ratio and Spatial Resolution in X-ray Electronic Imagers: Is the MTF A Relevant Parameter?,' Med. Phys., Vol. 27, Issue 1, pp. 86-93, 2000 https://doi.org/10.1118/1.598859
- Metz, C. E., Wagner, R. F., Doi, K., Brown, D. G., Nishikawa, R. M. and Myers, K. J., 'Toward Consensus on Quantitative Assessment of Medical Imaging Systems,' Med. Phys., Vol. 22, Issue 7, pp. 1057-1061, 1995 https://doi.org/10.1118/1.597511
- Wagner, R. F., Weaver, K. E., Denny, E. W. and Bostrom, R. G., 'Toward A Unified View of Radiological Imaging Systems. Part I: Noiseless Images,' Med. Phys., Vol. 1, Issue 1, pp. 11-24, 1974 https://doi.org/10.1118/1.1637272
- Kim, H. K., 'Sensor Technology for Digital Radiography,' J. of the KSPE, Vol. 22, No. 8, pp. 7-16, 2005
- Street, R. A., Nelson, S., Antonuk, L. and Perez-Mendez, V., 'Amorphous Silicon Sensor Arrays for Radiation Imaging,' Proc. Mater. Res., Vol. 192, pp. 441-452, 1990
- Rowlands, J. A. and Kasap, S., 'Amorphous Semiconductor Usher in Digital X-ray Imaging,' Phys. Today, Vol. 50, No. 11, pp. 24-30, 1997
- Kim, H. K., Lee, S. C., Cho, M. H., Lee, S.Y. and Cho, G., 'Use of A Flat-Panel Detector for Microtomography: A Feasibility Study for Small-Animal Imaging,' IEEE Trans. Nucl. Sci., Vol. 52, No. 1, pp. 193-198, 2005 https://doi.org/10.1109/TNS.2004.843107
- Fujita, K., Mori, H., Kyuushima, R., Honda, M. and Yamamoto, K., 'High Resolution Large Formatted CMOS Flat-Panel Sensors for X-ray,' IEEE Nucl. Sci. Symp. and Med. Imag. Conf., pp. 2114-2118, 2003
- Bigas, M., Cabruja, E., Forest, J. and Salvi, J., 'Review of CMOS Image Sensors,' Microelectronics Journal, Vol. 37, Issue 5, pp. 433-451, 2006 https://doi.org/10.1016/j.mejo.2005.07.002
- Kim, H. K., 'Cone-Beam Microtomography and Its Application,' J. of the KSPE, Vol. 22, No. 3, pp. 7-14, 2005
- Jaffray, D. A. and Siewerdsen, J. H., 'Cone-Beam Computed Tomography with A Flat-Panel Imager: Initial Performance Characterization,' Med. Phys., Vol. 27, Issue 6, pp. 1311-1322, 2000 https://doi.org/10.1118/1.599009
- Ning, R., Chen, B., Yu, R., Conover, D., Tang, X., and Ning, Y., 'Flat Panel Detector-Based Cone-Beam Volume CT Angiography Imaging: System Evaluation,' IEEE Trans. Med. Imag., Vol. 19, No. 9, pp. 949-963, 2000 https://doi.org/10.1109/42.887842
- Lee, S. C., Kim, H. K., Chun, I. K., Cho, M. H., Lee, S. Y. and Cho, M. H., 'A Flat-Panel Detector Based Micro-CT System: Performance Evaluation for Small-Animal Imaging,' Phys. Med. Biol., Vol. 48, Issue 24, pp. 4173-4185, 2003 https://doi.org/10.1088/0031-9155/48/24/014
- Barrett, H. H. and Swindell, W., 'Radiological Imaging - The Theory of Image Formation, Detection, and Processing,' New York: Academic Press, 1981
- Barrett, H. H. and Meyers, K. J., 'Foundations of Image Science,' New York: Wiley, 2004
- Sattarivand, M. and Cunningham, I. A., 'Computational Engine for Development of Complex Cascaded Models of Signal and Noise in X-ray Imaging Systems,' IEEE Trans. Med. Imag., Vol. 24, No. 2, pp. 211-222, 2005 https://doi.org/10.1109/TMI.2004.839680
- Rabbani, M., Shaw, R. and Van Metter, R., 'Detective Quantum Efficiency of Imaging Systems with Amplifying and Scattering Mechanisms,' J. Opt. Soc. Am. A, Vol. 4, Issue 5, pp. 895-901, 1987 https://doi.org/10.1364/JOSAA.4.000895
- Rabbani, M. and Van Metter, R., 'Analysis of Signal and Noise Propagation for Several Imaging Mechanisms,' J. Opt. Soc. Am. A, Vol. 6, Issue 8, pp. 1156-1164, 1989 https://doi.org/10.1364/JOSAA.6.001156
- Cunningham, I. A., Westmore, M. S. and Fenster, A., 'A Spatial-Frequency-Dependent Quantum Accounting Diagram and Detective Quantum Efficiency Model of Signal and Noise Propagation in Cascaded Imaging Systems,' Med. Phys., Vol. 21, Issue 3, pp. 417-427, 1994 https://doi.org/10.1118/1.597401
- Swank, R. K., 'Absorption and Noise in X-ray Phosphors,' J. Appl. Phys., Vol. 44, Issue 9, pp. 4199-4203, 1973 https://doi.org/10.1063/1.1662918
- Barrett, H. H., Wagner, R. F. and Myers, K. J., 'Correlated Point Processes in Radiological Imaging,' Proc. SPIE, Vol. 3032, pp. 110-125, 1997
- Lee, S. C., Kim, H. K., Chun, I. K., Cho, M. H., Cho, M. H. and Lee, S. Y., 'Development and Characterization of A Flat-Panel Detector-Based Microtomography System,' Key Eng. Mater., Vols. 270-273, pp. 1245-251, 2004
- Yao, J. and Cunningham, I. A., 'Parallel Cascades: New Ways to Describe Noise Transfer in Medical Imaging Systems,' Med. Phys., Vol. 28, Issue 10, pp. 2020-2038, 2001 https://doi.org/10.1118/1.1405842
- Kim, H. K., 'Generalized Cascaded Model to Assess Noise Transfer in Scintillator-Based X-ray Imaging Detectors,' Appl. Phys. Lett., Vol. 89, No. 23, p. 233-504, 2006