참고문헌
- Barron DJ, Rueggeberg FA, Schuster GS. A comparison of monomer conversion and inorganic filler content in visible light-cured denture resins. Dent Mater 1992;8:874-7
- Asmussen E. Restorative resins. Hardness and strength vs. quantity of remaining double bonds. Scand J Dent Res 1982;90:484-9
- Asmussen E. Factors affecting the quantity of remaining double bonds in restorative resin polymers. Scand J Dent Res 1982;90:490-6
- Bradford EW. Case of allergy to methyl-methacrylae. Br Dent J 1948;84:195
- Stungis TE, Fink JN. Hypersensitivity to acrylic resin. J Prosthet Dent 1969;22:425-8 https://doi.org/10.1016/0022-3913(69)90209-1
- Giunta JL, Grauer I, Zablotsky N. Allergic contact stomatitis caused by acrylic resin. J Prosthet Dent 1979;42:188-90 https://doi.org/10.1016/0022-3913(79)90173-2
- Ali A, Bates JF, Reynolds AJ, Walker DM. The burning mouth sensation related to the wearing of acrylic dentures: an investigation. Br Dent J 1986;161:444-7 https://doi.org/10.1038/sj.bdj.4806008
- Weaver RE, Goebel WM. Reactions to acrylic resin dental prostheses. J Prosthet Dent 1980;43:138-42 https://doi.org/10.1016/0022-3913(80)90176-6
- Ruyter IE, Gyorosi PP. An infrared spectroscopic study of sealants. Scand J Dent Res 1976;84:396-400
- Smith DC. Acrylic denture base. Residual monomer. Br Dent J 1958;105:86-91
- Austin AT, Basker RM. The level of residual monomers in acrylic denture base materials. Br Dent J 1980;149:281-6 https://doi.org/10.1038/sj.bdj.4804511
- Dogam A, Bek B, Cevik NN, Usanmaz A. The effect of preparation conditions of acrylic denture base materials on the level of residual monomer, mechanical properties and water adsorption. J Dent 1995;23:313-8 https://doi.org/10.1016/0300-5712(94)00002-W
- Koda T, Tsuchiya H, Yamauchi M, Hoshino Y, Takagi N, Kawano J. High-performance liquid chromatographic estimation of elutes from denture base polymers. J Dent 1989;17:84-9 https://doi.org/10.1016/0300-5712(89)90137-1
- Vallittu PK, Miettinium V, Alakuijala P. Residual monomer content and its release into water from denture base materials. Dent Mater 1995;11:338-42 https://doi.org/10.1016/0109-5641(95)80031-X
- Shim JS, Watts DC. Residual monomer concentration in denture-base acrylic resin after an additional, soft-liner, heat-cure cycle. Dent Mater 1999;15:296-300 https://doi.org/10.1016/S0109-5641(99)00048-2
- Lamb DJ, Ellis B, Priestley D. The effects of process variables on levels of residual monomer in autopolymerizing dental acrylic resin. J Dent 1983;11:80-8 https://doi.org/10.1016/0300-5712(83)90051-9
- Smith DC, Bains MED. The detection and estimation of residual monomer in polymethyl methacrylate. J Dent Res 1956;35:16-24 https://doi.org/10.1177/00220345560350010901
- Antonucci JM, Toth EE. Extent of polymerization of dental resins by differential scanning calorimetry. J Dent Res 1983;23:704-7
- Miyazaki K, Horibe TJ. Polymerization of multifunctional methacrylates and acrylates. J Biomed Mater Res 1988;22:1011-22 https://doi.org/10.1002/jbm.820221105
- Chung KH, Sharma B, Greener EH. Polymerization kinetics in dental acrylics. Dent Mater 1986;2:275-8 https://doi.org/10.1016/S0109-5641(86)80042-2
- Eliades GC, Vougiouklakis GJ, Caputo AA. Degree of double bond conversion in light-cured composites. Dent Mater 1987;3:19-25 https://doi.org/10.1016/S0109-5641(87)80055-6
- Rueggeberg FA. Determination of resin cure using infrared analysis without an internal standard. Dent Mater 1994;10:282-6 https://doi.org/10.1016/0109-5641(94)90076-0
- Duray SJ, Gilbert JL, Lautenschlager EP. Comparison of chemical analysis of residual monomer in a chemical-cured dental acrylic material to an FTIR method. Dent Mater 1997;3:240-5
- Ferracane JL, Greener EH. Fourier transform infrared analysis of degree of polymerization in unfilled resins- Methods comparison. J Dent Res 1984;63:1093-5 https://doi.org/10.1177/00220345840630081901
- Silikas N, Eliades G, Watts DC. Light intensity effects on resin-composite degree of conversion and shrinkage strain. Dent Mater 2000;16:292-6 https://doi.org/10.1016/S0109-5641(00)00020-8
- Stansbury JW, Dickens SH. Determination of double bond conversion in dental resins by near infrared spectroscopy. Dent Mater 2001;17:71-9 https://doi.org/10.1016/S0109-5641(00)00062-2
- Venhovan BAM, de Gee AJ, Davidson CL. Polymerization contraction and conversion of light-curing Bis-GMA-based methacrylate resins. Biomaterials 1993;14:871-5 https://doi.org/10.1016/0142-9612(93)90010-Y
- Rathbun MA, Craig RG, Hanks CT, Filisko FE. Cytotoxicity of a Bis-GMA dental composite before and after leaching in organic solvents. J Biomed Mater Res 1991;25:443-57 https://doi.org/10.1002/jbm.820250403
피인용 문헌
- ATR technique, an appropriate method for determining the degree of conversion in dental giomers vol.27, pp.12, 2016, https://doi.org/10.1088/0957-0233/27/12/124008
- Biomedical photopolymers in 3D printing vol.26, pp.2, 2020, https://doi.org/10.1108/rpj-10-2018-0268