DOI QR코드

DOI QR Code

Determination of Toxic Elements in Polymer Materials Using Instrumental Neutron Activation Analysis

  • Park, Kwang-Won (Division of Metrology for Quality Life, Korea Research Institute of Standards and Science) ;
  • Lee, Joung-Hae (Division of Metrology for Quality Life, Korea Research Institute of Standards and Science) ;
  • Cho, Kyung-Haeng (Division of Metrology for Quality Life, Korea Research Institute of Standards and Science) ;
  • Min, Hyung-Sik (Division of Metrology for Quality Life, Korea Research Institute of Standards and Science) ;
  • Lim, Myung-Chul (Division of Metrology for Quality Life, Korea Research Institute of Standards and Science) ;
  • Choi, Duk-Soo (Division of Metrology for Quality Life, Korea Research Institute of Standards and Science)
  • Published : 2008.07.20

Abstract

Polymer materials are very difficult to decompose for the purpose of chemical analysis. Nondestructive analysis without pretreatment provides a suitable solution that will overcome this obstacle. In this study, CRM candidate samples that contained toxic elements such as As, Cd, Cr and Zn in a polypropylene (PP) were analyzed using instrumental neutron activation analysis (INAA). The analytical results were obtained from ten samples selected by random sampling at two different concentration levels (low and high). Particular attention was paid to reducing analytical errors and evaluating the associated uncertainty.

Keywords

References

  1. Official Journal of the European Union, L37/19, Directive 2002/95/EC of the European Parliament and of the Council on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment; 2003
  2. European Commission Environment Directorate-General XI, Proposal for a Directive on Waste from Electrical and Electronic Equipment (WEEE), 3rd Draft Version; 1998
  3. Park, C. J.; Cho, K. H.; Suh, J. K.; Han, M. S. J. Anal. At. Spectrom. 2000, 14, 567
  4. Balla, M.; Molnar, Z.; Karos, A. J. Radioanal. Nucl. Chem. 2004, 259, 395 https://doi.org/10.1023/B:JRNC.0000020907.84246.49
  5. ISO/IEC Guide 34, Quality System Guidelines for the Production of Reference Materials; ISO, Geneva, 1996
  6. Zeisler, R.; Vajda, N.; Lamaze, G.; Molnar, G. L. Handbook of Nuclear Chemistry; Kluwer Academic Publishers: 2003; Vol. 3, p 303
  7. Zikovsky, L. Nucl. Instr. Meth. Phys. Res. 1984, B4, 421
  8. Firestone, R. B.; Shirley, V. S. Table of Isotopes, 8th ed.; Wiley: New York, 1996

Cited by

  1. -Toluidine Zirconium(IV) Iodosulfosalicylate-Based Ion-Selective Membrane Electrode for Potentiometric Determination of Cr(III) Ions and Its Analytical Applications vol.53, pp.39, 2014, https://doi.org/10.1021/ie501788a
  2. LA-ICP-MS analysis of waste polymer materials vol.398, pp.1, 2010, https://doi.org/10.1007/s00216-010-3963-6