References
- Svec, F.; Frechet, J. M. J. Anal. Chem. 1992, 64, 820-822 https://doi.org/10.1021/ac00031a022
- Minakuchi, H.; Nakanishi, N.; Soga, N.; Ishizuka, N.; Tanaka, N. Anal. Chem. 1996, 68, 3498-3501 https://doi.org/10.1021/ac960281m
- Zhu, G.; Zhang, L.; Yuan, H.; Liang, Z.; Zhang, W.; Zhang, Y. J. Sep. Sci. 2007, 30, 792-803 https://doi.org/10.1002/jssc.200600496
- Kato, M.; Sakai-Kato, K.; Toyo'oka, T. J. Sep. Sci. 2005, 28, 1893-1908 https://doi.org/10.1002/jssc.200500225
- Cabrera, K. J. Sep. Sci. 2004, 27, 843-852 https://doi.org/10.1002/jssc.200401827
- Legido-Quigley, C.; Marlin, N. D.; Melin, V.; Manz, A.; Smith, N. W. Electrophoresis 2003, 24, 917-944 https://doi.org/10.1002/elps.200390136
- Cheong, W. J.; Kang, G. W.; Lee, W. L.; Yoo, J.-S. J. Liq. Chrom. & Rel. Technol. 2002, 25, 1367-1378 https://doi.org/10.1081/JLC-120004752
- Cheong, W. J. J. Chromatogr. A 2005, 1066, 231-237 https://doi.org/10.1016/j.chroma.2005.01.011
- Cheong, W. J.; Seo, Y. J.; Park, S. T.; Kang, G. W. Bull. Korean Chem. Soc. 2006, 27, 1059-1062 https://doi.org/10.5012/bkcs.2006.27.7.1059
- Seo, Y. J.; Kang, G. W.; Park, S. T.; Moon, M.; Park, J. H.; Cheong, W. J. Bull. Korean Chem. Soc. 2007, 28, 999-1004 https://doi.org/10.5012/bkcs.2007.28.6.999
- Ivanov, A. R.; Zang, L.; Karger, B. L. Anal. Chem. 2003, 75, 5306-5316 https://doi.org/10.1021/ac030163g
- Chen, J. R.; Dulay, M. T.; Zare, R. N.; Svec, F.; Peters, E. Anal. Chem. 2000, 72, 1224-1227 https://doi.org/10.1021/ac9911793
- Legido-Quigley, C.; Smith, N. W. J. Chromatogr. A 2003, 1042, 61-68 https://doi.org/10.1016/j.chroma.2004.05.060
Cited by
- Fritting techniques in chromatography vol.37, pp.6, 2014, https://doi.org/10.1002/jssc.201301239
- Organic monolith frits encased in polyether ether ketone tubing with improved durability for liquid chromatography vol.38, pp.17, 2015, https://doi.org/10.1002/jssc.201500465
- Disposable microcolumns with welded metal frits vol.39, pp.2, 2015, https://doi.org/10.1002/jssc.201501055
- Polyether ether ketone encased monolith frits made of polyether ether ketone tubing with a 0.25 mm opening resulting in an improved separation performance in liquid chromatography vol.39, pp.10, 2016, https://doi.org/10.1002/jssc.201600040
- Use of chain transfer agent attached to silica particles in preparation of polystyrene-based stationary phases vol.33, pp.4-5, 2010, https://doi.org/10.1002/jssc.200900578
- A New Stationary Phase with Improved Ligand Morphology Prepared by Polymerization of Styrene upon Initiator-attached Lichorsorb Silica Particles vol.30, pp.12, 2008, https://doi.org/10.5012/bkcs.2009.30.12.3127
- A New Stationary Phase Prepared by Polymerization of Styrene on Initiator Bonded Porous Silica vol.30, pp.3, 2009, https://doi.org/10.5012/bkcs.2009.30.3.722
- Disposable Microcolumn with a Welded Metal Frit and a Silver Cement Frit vol.40, pp.6, 2019, https://doi.org/10.1002/bkcs.11710