DOI QR코드

DOI QR Code

A New Selective Membrane Electrode for Oxalate Based on N,N'-Bis(salicylidene)-2,2-dimethylpropane-1,3-diamine Ni(II)

  • Ardakani, M.Mazloum (Department of Chemistry, Faculty of Science, Yazd University) ;
  • Iranpoor, F. (Department of Chemistry, Ardakan Payam Noor University) ;
  • Karimi, M.A. (Department of Chemistry, Faculty of Science, Shahid Bahonar University) ;
  • Salavati-Niasari, M. (Department of Chemistry, Faculty of Science, University of Kashan, Kashan, Iran)
  • Published : 2008.02.20

Abstract

A new solvent polymeric membrane electrode, based on N,N'-bis(salicylidene)-2,2-dimethylpropane-1,3-diamine Ni(II) as the ionophore, was designed. The oxalate-selective electrode has the dynamic range between 1.0 10-6 M and 1.0 10-1 M with a Nernstian slope of -28.7 1.0 mV per decade. The detection limit was 6.3 10-7 M. The proposed electrode revealed good selectivities for oxalate over a variety of other anions and could be used in a pH range of 2.0-7.8. The electrode can be used for at least two months without any considerable divergence in potential. The designed electrode was applied as an indicator electrode in the potentiometric determination of oxalate in real samples.

Keywords

References

  1. Umezawa, Y. Handbook of Ion-selective Electrodes: Selectivity Coefficients; CRC Press: Boca Raton, FL, 1990
  2. Bakker, E.; Pretsch, E.; Buhlmann, P. Chem. Rev. 1998, 98, 1593 https://doi.org/10.1021/cr970113+
  3. Meyerhoff, M. E. Trends Anal. Chem. 1993, 12, 257 https://doi.org/10.1016/0165-9936(93)87065-6
  4. Daunert, S.; Wallace, S.; Florido, A.; Bachas, L. G. Anal. Chem. 1991, 63, 1676 https://doi.org/10.1021/ac00017a005
  5. Liu, D.; Chen, W. C.; Yang, R. H.; Shen, G. L.; Yu, R. Q. Anal. Chim. Acta 1997, 338, 209 https://doi.org/10.1016/S0003-2670(96)00382-0
  6. Rothmaier, M.; Schaller, W.; Morf, W. E.; Pretsch, E. Anal. Chim. Acta 1996, 327, 17 https://doi.org/10.1016/0003-2670(96)00055-4
  7. El Aamrami, F. Z.; Saster, A.; Aguilar, M.; Beyer, L.; Floridi, A. Anal. Chim. Acta 1996, 329, 247 https://doi.org/10.1016/0003-2670(96)00115-8
  8. Chaniotakis, N. A.; Park, S. B.; Meyerhoff, M. E. Anal. Chem. 1989, 61, 566 https://doi.org/10.1021/ac00181a013
  9. Li, J. Z.; Pang, X. Y.; Gao, D.; Yu, R. Q. Talanta 1995, 42, 1775 https://doi.org/10.1016/0039-9140(95)01639-2
  10. Hisamoto, H.; Siswanta, D.; Nishihara, H.; Suzuki, K. Anal. Chim. Acta 1995, 304, 171 https://doi.org/10.1016/0003-2670(94)00614-R
  11. Zhang, Z. Q.; Xu, X. Q. Anal. Chim. Acta 2000, 406, 303 https://doi.org/10.1016/S0003-2670(99)00773-4
  12. Infants, J. A.; Luque, M. D.; Valcarcel, M. Anal. Chim. Acta 1991, 242, 179 https://doi.org/10.1016/0003-2670(91)87061-B
  13. Fogg, A. G.; Alonso, R. M.; Fenandez, M. A. Analyst 1986, 111, 249 https://doi.org/10.1039/an9861100249
  14. Alnnaibd, A. M.; Townhend, A. Anal. Chim. Acta 1989, 218, 1 https://doi.org/10.1016/S0003-2670(00)80277-9
  15. Leon, L. E.; Rois, A.; Luque, M. D.; Valcarcel, M. Analyst 1990, 115, 1549 https://doi.org/10.1039/an9901501549
  16. Leon, L. E.; Rois, A.; Luque, M. D.; Valcarcel, M. Anal. Chim. Acta 1990, 234, 227 https://doi.org/10.1016/S0003-2670(00)83561-8
  17. Perez-Raiz, T.; Martinez, C.; Tomas, V.; Casajus, R. Analyst 1995, 120, 2111 https://doi.org/10.1039/an9952002111
  18. Stefan, R. I.; Draghici, I.; Baiulescu, G. E. Sensors and Actuators B 2000, 65, 250-252 https://doi.org/10.1016/S0925-4005(99)00344-5
  19. Mazloum Ardakani, M.; Jalayer, M.; Naeimi, H.; Heidarnezhad, A.; Zare, H. R. Biosens. & Bioelect. 2006, 21, 1156-1162 https://doi.org/10.1016/j.bios.2005.04.013
  20. Perez-Raiz, T.; Martinez, C.; San, A.; Val, V. Anal. Chem. Acta 1993, 284, 1973
  21. Zara, A. J.; Bulbore, L. O. Anal. Lett. 1987, 20, 213 https://doi.org/10.1080/00032718708064561
  22. Chen, Y.; Li, Q.; Yang, Z.; Zhang, F. Chiniese J. Chromatogr. 1989, 7, 226
  23. Utzman, S. J. Chromatogr. 1993, 640, 282
  24. Brega, A.; Quadri, A. J. Liq. Chromatogr. 1992, 15, 501 https://doi.org/10.1080/10826079208017187
  25. Mazloum Ardakani, M.; Salavati-Niasari, M.; Sadeghi, A. New. J. Chem. 2004, 28, 595 https://doi.org/10.1039/b400681j
  26. Kamata, S.; Bhal, A.; Fakunaga, Y.; Marata, A. Anal. Chem. 1998, 60, 2464 https://doi.org/10.1021/ac00173a006
  27. Shamsipur, M.; Khayatian, G.; Tangestaninejad, S. Electroanalysis 1999, 18, 1340
  28. Rouhollahi, A.; Shamsipur, M. Anal. Chem. 1999, 71, 1350 https://doi.org/10.1021/ac981077x
  29. Farhadi, K. H.; Maleki, R.; Shamsipur, M. Electroanalysis 2002, 14, 760 https://doi.org/10.1002/1521-4109(200206)14:11<760::AID-ELAN760>3.0.CO;2-Q
  30. Bakker, E.; Buhlmann, P.; Prestch, E. Chem. Rev. 1997, 97, 3033
  31. Shamsipur, M.; Kazemi, S. Y.; Niknam, K.; Sharghi, H. Bull. Korean Chem. Soc. 2002, 23, 53 https://doi.org/10.5012/bkcs.2002.23.1.053
  32. Amini, M. K.; Rafi, A.; Ghaedi, M.; Habibi, H.; Zohory, M. M. Microchemical Journal 2003, 75, 143 https://doi.org/10.1016/S0026-265X(03)00091-2
  33. De Backer, B. L.; Nagels, L. G.; Alderweireldt, F. C. Anal. Chim. Acta 1993, 273, 449 https://doi.org/10.1016/0003-2670(93)80190-V
  34. Oesch, U.; Simon, W. Anal. Chem. 1980, 52, 692 https://doi.org/10.1021/ac50054a024
  35. Verpoorte, E. M. J.; Chan, A. D. C.; Harrison, D. Electroanalysis 1993, 5, 845 https://doi.org/10.1002/elan.1140050920
  36. Mathison, S.; Bakker, E. Anal. Chem. 1989, 70, 303
  37. Gadzepko, V. P.; Christian, G. D. Anal. Chim. Acta 1984, 164, 279 https://doi.org/10.1016/S0003-2670(00)85640-8
  38. Umezawa, Y.; Umezawa, K.; Sato, H. Pure Appl. Chem. 1995, 67, 507 https://doi.org/10.1351/pac199567030507
  39. Bakker, E. Electroanalysis 1997, 9, 7 https://doi.org/10.1002/elan.1140090103
  40. Baily, P. L. In Analysis with Ion-Selective Electrodes; Heyden: London, 1996
  41. Hofmeister, P. Arch. Exp. Pathol. Pharmacol. 1888, 24, 247 https://doi.org/10.1007/BF01918191

Cited by

  1. An oxalate-selective electrode and its application to analysis vol.70, pp.7, 2015, https://doi.org/10.1134/S1061934815070126
  2. Highly Selective Potentiometric Oxalate Ion Sensors Based on Ni(II) Bis-(m-aminoacetophenone)ethylenediamine vol.28, pp.7, 2008, https://doi.org/10.1002/cjoc.201090198
  3. Oxalate membrane-selective electrode based on surfactant-modified zeolite vol.56, pp.22, 2008, https://doi.org/10.1016/j.electacta.2011.02.069