References
- D. Huang, E. A. Swanson, C. P. Lin, J. S. Shuman, W. G Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Pulialito, and J. G. Fujimoto, 'Optical coherence tomography', Science, 254, pp. 1178- 1181, 1991 https://doi.org/10.1126/science.1957169
- B. E. Bouma and G. J. Teamey, 'Handbook of optical coherence tomography', Marcel Dekker, Inc., 2002
- J. M. Schmitt, 'Optical coherence tomography (OCT): A Review', IEEE J. selected topics in quantum electronics, vol. 5, no. 4, pp. 1205-1215, 2007 https://doi.org/10.1109/2944.796348
- Z. Chen, T. E. Milner, D. Dave, and J. Stuart Nelson 'Optical doppler tomographic imaging of fluid flow velocity in highly scattering media', Optics Letters, vol. 22, no. 1, pp. 64-66, 1997 https://doi.org/10.1364/OL.22.000064
- B. Cense, M. Mujat, T. C. Chen, and J. F. Boer, 'Polarization-sensitive spectral-domain optical coherence tomography using a single line scan camera', Optics Express, vol. 15, no. 5, pp. 2421-2431, 2007 https://doi.org/10.1364/OE.15.002421
- B. C. Shin and J. R. Kwon, 'Ultrasonic transducer application for nondestructive testing of continuous cast billets', J. Kor. Sensors Soc., vol. 5, no. 3, pp. 25-31, 1996
- Y. Cheng and K. V. Larin, 'Artificial fingerprint recognition by using optical coherence tomography with autocorrelation analysis', Applied Optics, vol. 45, no. 36, pp. 9238-9245, 2006 https://doi.org/10.1364/AO.45.009238
- C. M. Choi and R.G. Bennett, 'Laser dopplers to determine cutaneous blood flow', Dermatol. Surg., vol. 29, no.3, pp. 272-280, 2003 https://doi.org/10.1046/j.1524-4725.2003.29042.x
- G. J. Tearney, B. E. Bouma, and J. G. Fujimoto, 'High-speed phase- and group-delay scanning with a grating-based phase control delay line', Optics Letters, vol. 22, no. 23, pp.1811-1813, 1997 https://doi.org/10.1364/OL.22.001811
- A. Rollins, S. Yazdanfar, M. Kulkarni, R. Ung-Arunyawee, and J. Izatt, 'In vivo video rate optical coherence tomography', Optics Express, vol. 3, no. 6, pp. 219-229, 1998 https://doi.org/10.1364/OE.3.000219
- X. Liu, M. J. Cobb, and X. Li, 'Rapid scanning allreflective optical delay line for real-time optical coherence tomography', Optics Letters, vol. 29, no 1, pp. 80-82, 2004 https://doi.org/10.1364/OL.29.000080
- R. J. Adrian and C. S. Yao, 'Power spectra of fluid velocities measured by laser Doppler velocimetry', Experiments in Fluids, vol. 5, no. 1, pp. 17-28, 1987
- C. D. Meinhart, S. T. Wereley, and J. G. Santiago, 'PIV measurements of a microchannel flow', Experiments in Fluids, vol. 27, no. 5, pp. 414-419, 1999 https://doi.org/10.1007/s003480050366
- H. H. Choi and E. H. Lee, 'A study on the development of ultrasound urine volume detection sensor and the correlation between urine volume and bladder interwall distance', J. Kor. Sensors Soc., vol. 9, no. 4, pp. 256-266, 2000
- M. H. Frosz, M. Juhl, and M. H. Lang, 'Optical coherence tomography: system design and noise anaylysis', RiO National Laboratory, 2001. 78