CIM Based Zero Voltage Switching of Energy Recovery Sustain Driver for AC PDPs with Reduced Sustain Voltage

CIM을 이용한 유지구동전압 반감형 AC PDP용 에너지 회수 구동회로의 영전압 스위칭

  • Published : 2007.10.20

Abstract

AC PDP has disadvantages that power consumption and sustain voltage are high. An energy recovery circuit for AC PDPs with reduced sustain voltage was proposed to solve these disadvantages. However, the circuit has disadvantage that the switching elements are performed hard switching at the start point of discharge and sustaining region. The reason is that the panel voltage is lower than sustain voltage at that point. In this paper, we propose the improved driving method that switching devices are operated with ZVS by using CIM(Current Infection Method) also at that point. CIM region is designed by theoretical circuit analysis. Finally, the validity of the proposed driving method is verified by the simulations and experimentation.

AC PDP(Plasma Display Panel)는 소비전력이 크고 유지구동전압이 높다는 단점이 있다. 이런 단점을 개선하기 위하여 에너지 회수회로를 설치하고 유지구동전압을 낮춘 회로가 제안되었다. 그러나 이 회로는 방전유지 구간 시작 시점에서 패널의 전압이 방전유지구동전압보다 낮기 때문에 스위칭소자들이 하드 스위칭 동작을 하는 단점이 있다. 본 논문에서는 CIM(Current Injection Method)을 이용하여 미리 인덕터에 전류를 흘려주어 방전유지 구간 시작 시점에서도 스위칭소자들이 영전압 스위칭동작을 하여 전 구간에서 영전압 스위칭 또는 영전류 스위칭동작을 할 수 있는 새로운 구동방식을 제안한다. 그리고 회로를 해석하여 CIM 구간을 설계하고 시뮬레이션과 실험을 통하여 유용성을 입증하였다.

Keywords

References

  1. 유종걸, 홍순찬, 'AC PDP용 NPC 타입 멀티레벨 에너지 회수회로에 관한 연구', 전력전자학회 논문지, 제10권, 제2호, pp. 194-202, 2005. 4
  2. 홍순찬, 임승범, '새로운 유지구동전압 저감형 AC PDP 용 에너지 회수회로', 전력전자학회 논문지, 제11권, 제6 호, pp. 494-501, 2006
  3. Jun-Young Lee, Jin-Sung Kim, Nam-Sung Jung, and Bo-Hyung Cho, 'The Current Injection Method for AC Plasma Display Panel Sustainer', IEEE Transactions on Industrial Electronics, Vol. 51, No. 3, pp. 615-624, 2004, June https://doi.org/10.1109/TIE.2004.825359