Abstract
As the industry of 21C has been developed, the gas industry has grown and it has not only the convenience but also the riskiness fer using. Especially, the energy and environment problems have been getting serious after the modern industry revolution. Therefore, the demand of gas as an eco-friendly energy source is getting increased. With the demand of gas, the installation and use of gas boiler is also increased, so human life injury by the waste gas(CO) of boiler goes on increasing every year. Therefore, we want to find out the harm to human body through the study on the concentration of CO by the length of the curved exhaust tube of boiler. The allowable concentration of CO is 50ppm. The length of the one-meter-three-curved tube after three minutes is applicable to 50ppm of the threshold limit values of CO. Also, five meters exceed the threshold limit values of CO after five minutes. Strangely, the concentration of CO is under the threshold limit values from two to four meters.
21C 산업의 발전과 더불어 급증하고 있는 가스산업은 사용의 편리성과 위험성을 공존하고 있다. 특히 근대 산업혁명 이후 에너지 및 환경에 대한 문제가 두각을 나타내게 되었다. 따라서 환경친화적인 에너지원으로서 가스의 수요가 날로 급증하고 있다. 가스의 수요와 더불어 가스보일러의 설치 및 사용이 늘어나면서 보일러 폐가스(CO)에 의한 인명피해가 해마다 증가하고 있다. 따라서 본 논문의 목적은 보일러 곡관 배기통의 길이에 따른 CO농도의 고찰을 통하여 인체에 대한 위해성을 파악코자 함이다. CO의 허용농도인 50ppm에 해당하는 길이는 3곡관 1m에서 3분이 경과할 경우이다. 또한, 5m에서는 5분 경과부터 CO농도가 허용농도를 초과하는 것으로 나타났다. 특이하게 2m부터 4m까지는 CO농도가 허용농도 이하였다.