References
- Y. Hanein, C. Schabmueller, G. Holman, P. Lucke, D. Denton and K. Bohringer, 'High aspect ratio submicrometer needles for intracellular applications', J. Micromech. Microeng. vol. 13, pp. 91-95, 2003 https://doi.org/10.1088/0960-1317/13/4/315
- L. Lin and A. Pisano, 'Silicon processed microneedles', IEEE J. Microelectromech. Syst. vol. 8, pp. 78-84, 1999 https://doi.org/10.1109/84.749406
- K. Wise, D. Anderson, J. Hetke, D. Kipke and K. Najafi, 'Wireless implantable microsystcrns: High density electronic interfaces to the nervous system', Proceedings of the IEEE vol. 92, pp. 76-97, 2004
- Q. Bai and K. D. Wise, 'Single unit neural recording with active microelectrode arrays', IEEE Trans. Biomed. Eng. vol. 48, pp. 911-920, 2001 https://doi.org/10.1109/10.936367
- P. Rousche and R. Normann, 'Chronic intracortical micro stimulation of cat sensory cortex using the utahintracortical electrode array', IEEE Trans. Rehabilitation Eng. vol. 7, pp. 56-68, 1999 https://doi.org/10.1109/86.750552
- Q. Bai, K. Wise and D. Anderson, 'A high yield microassembly structure for three dimensional microelectrode arrays', IEEE Trans. Biomed. Eng. vol.47, pp. 281-289, 2000 https://doi.org/10.1109/10.827288
- J. Chen, K. Wise, J. Hetke and S. Bledsoe, 'A multichannel neural probe for selective chemical delivery at the cellular level', IEEE Trans. Biomed. Eng. vol. 44, pp. 760-769, 1997 https://doi.org/10.1109/10.605435
- S. Massia, M. Holecko and G. Ehteshami, 'In vitro assessment of bioactive coatings for neural implant applications', J. Biomed Mater Res. vol. 68, pp. 177 -186, 2003
- T. Stieglitz, M. Gross, 'Flexible BIOMEMS with electrode arrangements on front and back side as key component in neural prostheses and biohybrid systems,' Sensors Actuator B, Vol. 83, pp. 8-14, 2002 https://doi.org/10.1016/S0925-4005(01)01021-8
- P.J. Rousche, D.S. Pellinen, D.P. Pivis, J.C. Williams, D. Kipke, 'Flexible polyimide-based intracortical electrode arrays with bioactive capability,' IEEE Trans. Biomed. Eng, Vol. 48, pp. 361-371, 2001 https://doi.org/10.1109/10.914800
- T. Shoji, S. Takafumi, M. Kunihiko, and F. Hiroyuki, '3D flexible multichannel neural probe array,' J. Micromech. Microeng, Vol. 14, pp. 104-107, 2004 https://doi.org/10.1088/0960-1317/14/1/014
- K. K Lee, J. He, A. Singh, S. Massia, G. Ehteshami, B. Kim and G. Raupp, 'Polyimide-base introcortical neural implant with improbed structural stiffness,' J. Micromech. Microeng, Vol. 14, pp. 32-37, 2004 https://doi.org/10.1088/0960-1317/14/1/305
- Zen-Jei Wei, Yung-Yun Wang, Chi-Chao Wan, Chen-He Huang, 'Study of wetters in nickel electroforming of 3D microstructures'. Materials Chemistry and Physics Vol. 63, pp. 235-239, 2000 https://doi.org/10.1016/S0254-0584(99)00228-X
- Y. Hanein, K. Bohringer, R. Wyeth and A. Willows, 'Towards MEMS probes for intracellular recording', Sensors update Vol. 10, pp. 47-75 2002 https://doi.org/10.1002/1616-8984(20021)10:1<47::AID-SEUP47>3.0.CO;2-A