DOI QR코드

DOI QR Code

Design and Fabrication of Isolator for Mobile Repeater

이동통신 중계기용 아이솔레이터의 설계 및 제작

  • 정승우 (원광대학교 공과대학 전기전자 및 정보공학부) ;
  • 정윤환 (원광대학교 공과대학 전기전자 및 정보공학부) ;
  • 박노준 (원광대학교 공과대학 전기전자 및 정보공학부) ;
  • 강영진 (원광대학교 공과대학 전기전자 및 정보공학부) ;
  • 최우성 (원광대학교 공과대학 전기전자 및 정보공학부)
  • Published : 2007.09.29

Abstract

The lumped element isolators with temperature compensation magnetic circuits were designed in this paper. Isolators for mobile repeater at each band of K-PCS, GSM1900, W-CDMA, WiBro were fabricated by using optimum parameters of EM simulation, Form the results of this study, first of all, insertion loss at K-PCS band was below 0.2 dB and return loss was over 25dB. The bandwidth in isolation 23dB was found 30 MHz. Secondly, the figures of both losses at GSM1900 were 0.25dB and 23dB, respectively. The measured bandwidth in isolation 30dB was 60MHz. Thirdly, the losses at W-CDMA band were 0.15dB and 25dB. The bandwidth in isolation 24.8dB was found 60Mhz. Finally, the figures of both losses at Wibro band were 0.25dB and 23dB, respectively. The measured bandwidth in isolation 22.1dB was 100Mhz. In addition, the results of measured IMD were shown from 76.4dBc to 80.1dBc.

본 논문에서는 온도보상 자기회로를 갖는 집중정수형 아이솔레이터를 설계하고 전자계 시뮬레이션을 통한 최적 파라미터를 이용하여 각각 K-PCS, GSM1900, W-CDMA, WiBro 대역의 이동통신 중계기용 아이솔레이터를 제작하였으며 IMD 특성을 평가하였다. 결과로서 K-PCS 대역의 경우에 Insertion loss와 Return loss는 각각 0.2dB 이하, 25dB이상, Isolation 23dB에서 대역폭은 30MHz이었고 GSM1900의 경우에는 각각 0.25dB, 23dB, Isolation 30 dB에서 대역폭은 60 MHz이었으며 W-CDMA의 경우에는 각각 0.15dB, 25dB, Isolation 24.8 dB테서 대역폭은 60 MHz이었다. 또한 WiBro 대역의 경우에는 각각 0.25dB, 23dB 이상, Isolation 22.1dB에서 대역폭은 100MHz이었고 IMD측정 결과는 $76.4dBc{\sim}80.1dBc$이었으며 기존의 제품에 비하여 우수한 특성을 가지고 있음을 확인하였다.

Keywords

References

  1. Douglas K.Linkhart, Microwave Circulator Design, Artech House, 1989
  2. David M.Pozar, Microwave Engineering, Addison-Wesley, 1996
  3. H.Bosma, 'On stripline Y-circulation at UHF,' IEEE Trans. Microwave Theory Tech., Vol.12, pp. 61-72, Jan. 1964 https://doi.org/10.1109/TMTT.1964.1125753
  4. Y.Konishi, 'Lumped element Y circulator,' IEEE Trans. Microwave Theory Tech., Vol.13,pp.825-964,NOY.1965
  5. J.Deutsch and B. Wieser, 'Resonance Isolator and Y Circulator with Lumped Element at VHF,' IEEE Trans. Magnetics, Vol.2, no.3, pp.278-282, Sep. 1966 https://doi.org/10.1109/TMAG.1966.1065837
  6. J.Helszjn and M. McDermott, 'The inductance of a Lumped Constant Circulator,' IEEE Trans. Microwave Theory Tech, Vol.18, pp. 50-52, Jan. 1970 https://doi.org/10.1109/TMTT.1970.1127135
  7. R.H.Knerr, C.E.Barnes and F.Bosch, 'A compact broadband thin-film lumped element L-band circulator,' IEEE Trans. Microwave Theory Tech., Vol.18, pp.1100-1108, Jan. 1970 https://doi.org/10.1109/TMTT.1970.1127418
  8. R.E.Neidert, 'Losses in Y-Junction Stripline and Microstrip Feffite Circulator,' IEEE Trans. Microwave Theory Tech., Vol.41, pp. 1081-1086, Jun. 1993 https://doi.org/10.1109/22.238531