Development of Ultrasound Diagnostic System for Functional Gastrointestinal Disorders using Finite Difference Method

유한차분법을 이용한 기능성 위장 장애 진단용 초음파 시스템의 개발

  • 박원필 (연세대학교 보건과학대학 의공학부, 의료공학연구원) ;
  • 우대곤 (연세대학교 보건과학대학 의공학부, 의료공학연구원) ;
  • 고창용 (연세대학교 보건과학대학 의공학부, 의료공학연구원) ;
  • 이균정 (연세대학교 보건과학대학 의공학부, 의료공학연구원) ;
  • 이용흠 (연세대학교 보건과학대학 의공학부, 의료공학연구원) ;
  • 최서형 (하나한방병원, 하나의원) ;
  • 신태민 (연세대학교 보건과학대학 의공학부, 의료공학연구원) ;
  • 김한성 (연세대학교 보건과학대학 의공학부, 의료공학연구원) ;
  • 임도형 (연세대학교 보건과학대학 의공학부, 의료공학연구원)
  • Published : 2007.09.01

Abstract

The disaster from functional gastrointestinal disorders (FGID) has detrimental impact on the quality of life of the affected population. There are, however, rare diagnostic methods for FGID. Our research group identified recently that the gastrointestinal tract well of the patients with FGID became more rigid than that of healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The objective of the current study is, therefore, to identify feasibility of a diagnostic system for FGID based on ultrasound technique, which can quantify the characteristics above. Two-dimensional finite difference (FD) models (one normal and two rigid models) were developed to analyze the reflective characteristic (displacement) on each soft-tissue layer responded after application of ultrasound signals. Based on the results from FD analysis, the ultrasound system for diagnosis of the FGID was developed and clinically tested via application of it to 40 human subjects with/without FGID who were assigned to Normal and Patient Groups. The results from FD analysis showed that the maximum displacement amplitude in the rigid models (0.12 and 0.16) at the interface between the fat and muscle layers was explicitly less than that in the normal model (0.29). The results from actual specimens showed that the maximum amplitude of the ultrasound reflective signal in the rigid models $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal model $(0.1{\pm}0.0Vp-p)$. Clinical tests using our customized ultrasound system showed that the maximum amplitudes of the ultrasound reflective signals near to the gastrointestinal tract well for the patient group $(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group $(0.1{\pm}0.2Vp-p)$. These findings suggest that our customized ultrasound system using the ultrasound reflective signal may be helpful to the diagnosis of the FGID.

Keywords

References

  1. International Foundation for Functional Gastointestinal Disorders, 'Gastointestinal functional and motility disorders,' Available: http://www.iffgd.org/ GIDisoders/Glmain.html, 2006
  2. The Hankoyreh, 'About the Functional Gastrointestinal Disturbance,' Article of The Hankoyreh, Available to http://www.hanLco.kr/section-00510003112004/02/0051000312004022419 50615.html, 2004
  3. Talley, N. J., Stanghellini, V., Heading, R. C., Koch, K. L., Malagelada, J. R. and Tytgat, G N., 'Functional gastrointestinal disorders,' Gut, Vol. 45, pp. 1137-1142, 1999
  4. Thompson, W. G, Longstreth, G F., Drossman, D. A., Heaton, K. W., Irvine, E. J. and Muller-Lissner, S. A., 'Functional bowel disorders and functional abdominal pain,' Gut, Vol. 45, pp. 1143-1147, 1999
  5. Rubin, C., Bolander, M., Ryaby, J. and Hadjiargyrou, M., 'The use of low-intensity ultrasound to accelerate the healing of fractures,' The Journal of Bone & Joint Surgery, Vol. 83A, No.2, pp. 259-270, 2001
  6. Brown, R. J., 'How safe is diagnostic ultrasonography,' Canadian Medical Association Journal, Vol. 131, No.4, pp. 307-311, 1984
  7. Whittingham, T. A., 'Medical diagnostic applications and sources,' Progress in Biophysics and Molecular Biology, Vol. 93, Issues 1-3, pp. 84-110, 2007 https://doi.org/10.1016/j.pbiomolbio.2006.07.002
  8. Lee, Q. J., Lee, Y. H. and Shin, T. M., 'The Development and Response Characteristic Analysis of Dam Jerk Diagnosis System Using Ultrasonic Sensor,' Journal of Korean Institute of Electrical Engineering, Vol. 55D, No.4, pp. 189-194,2006
  9. Lehmann, J. F., 'Therapeutic Heat and Cold: Rehabilitation Medicine Library 3rd ed.,' Williams & Wilkins, pp. 133-171, 1982
  10. Auld, B. A., 'Acoustic fields and waves in solids 2nd ed.,' Krieger Publishing Company, Vol. 1, pp. 33-100, 1990
  11. Schechter, R. S., Chaskelis, H. H., Mignogna, R. B. and Delsanto, P. P., 'Real-time parallel computation and visualization of ultrasonic pulses in solids,' Science, Vol. 265, No. 5176, pp. 1188-1192, 1994 https://doi.org/10.1126/science.265.5176.1188
  12. Oomens, C. W. J., Bressers, O. F. J. T., Bosboom, E. M. H., Bouten, C. V. C. and Bader, D. L., 'Can loaded interface characteristics influence strain distributions in muscle adjacent to bony prominences?,' Computer methods in biomechanics and biomedical engineering, Vol. 6, No.3, pp. 171-180,2003 https://doi.org/10.1080/1025584031000121034
  13. Keef, K.D., Murray, D.C., Sanders, K.M. and Smith, T.K., 'Basal release of nitric oxide induces an oscillatory motor pattern in canine colon,' Journal of Physiology, Vol. 499, Part 3, pp. 773-786,1997 https://doi.org/10.1113/jphysiol.1997.sp021968
  14. Min, K. W. and Leabu, M., 'Interstitial Cells of Cajal (ICC) and Gastrointestinal Stromal Tumor (GIST): facts, speculations, and myths,' Journal of Cellular and Molecular Medicine, Vol. 10, No.4, pp. 995-1013,2006 https://doi.org/10.1111/j.1582-4934.2006.tb00541.x
  15. Smith, T. K., Reed, J. B. and Sanders, K. M., 'Interaction of two electrical pacemakers in the muscularis of the canine proximal colon,' American Journal of Physiology, Vol. 252, Issue 3, pp. C290-C299, 1987
  16. Takaki, M., 'Cut pacemaker cells: the interstitial cells of cajal (ICC),' Journal of Smooth Muscle Research, Vol. 39, pp. 137-161,2003 https://doi.org/10.1540/jsmr.39.137
  17. Fung, Y. C., 'Biomechanics: Mechanical Properties of Living Tissues 2nd ed.,' Springer-Verlag, pp. 269-277,1993
  18. Park, J. B. and Lakes, R. S., 'Biornaterials: An Introduction 2nd ed.,' Plenum Press, pp. 185-222, 1992
  19. ABAQUS Inc., 'Elastic Mechanical Properties: Hyperelasticity in ABAQUS Analysis User's Manual of ABAQUS Version 6.4 Documentation,' ABAQUS Inc., Vol. 3, pp. 10.5.1.1-23, 2006
  20. Wells, P. N. T., 'Biomedical Ultrasonics,' Academic Press, pp. 146-163, 1977
  21. Guyton, A. C. and Hall, J. E., 'Textbook of medical physiology 10 Ed.,' W. B. Saunders, pp. 67-95, 2000