Abstract
To obtain design data for built-up beams used as headers in light-frame timber construction, three members of $2{\times}6$ ($38{\times}140 mm$), $2{\times}8$ ($38{\times}184 mm$), $2{\times}10$ ($38{\times}235 mm$) and $2{\times}12$ ($38{\times}286 mm$) were built up as specimens of bending tests. The bending strengths of built-up headers were obtained through bending tests of these specimens, and it was considered that span tables can be calculated for various loading conditions based on the bending strengths of built-up headers. The bending strengths of built-up headers were determined as the bending stresses at 10 mm deflection of specimens from the results of bending tests of built-up beam specimens. Span tables for built-up headers were considered to be obtained by assuming five loading conditions for headers used in exterior walls and two loading conditions for headers used in interior walls. Among these 7 loading conditions, 5 loading conditions applied to headers in exterior walls included dead loads, live loads and snow loads and 2 loading conditions applied to headers in interior walls included dead loads and live loads.
경골목조건축공법에서 개구부의 헤더로 많이 사용되는 조립보에 대한 설계자료를 구하기 위하여 $2{\times}6$ ($38{\times}140 mm$), $2{\times}8$ ($38{\times}184 mm$), $2{\times}10$ ($38{\times}235 mm$) 및 $2{\times}12$ ($38{\times}286 mm$) 부재를 3개 겹쳐서 휨 시험편을 제작하였다. 이들에 대한 휨 시험을 통하여 조립보에 대한 허용응력을 구하고 허용응력에 근거하여 여러 가지 하중 조건에 대한 경간표를 작성하였다. 조립보에 대한 휨 시험 결과로부터 10 mm의 처짐이 발생할 때의 휨응력을 조립보 헤더의 휨강도로 산정하였다. 조립보에 대한 경간표는 외벽에서 헤더가 사용되는 위치에 따른 5가지 하중조건과 내벽에서 헤더가 사용되는 위치에 따른 2가지 하중조건을 고려하여 작성할 수 있는 것으로 생각된다. 총 7가지 하중 조건에 있어서 외벽에 사용되는 헤더에 대한 5가지 하중조건에서는 고정하중, 활화중 및 적설하중이 포함되었으며 내벽에 사용되는 헤더에 대한 2가지 하중조건에서는 고정하중과 활하중이 포함되었다.