Performance Analysis of a Parallel System Having a Cold Standby Unit

  • Sharma, S.C. (Department of Statistics, J. V. College) ;
  • Bae, S. (Department of Biostatistics, School of Public Health UNT Health Science Center) ;
  • Baek, J.B. (Department of Safety Engineering, Chungju National University) ;
  • Singh, K.P. (Department of Biostatistics, School of Public Health UNT Health Science Center)
  • Published : 2007.06.30

Abstract

This paper deals with the effectiveness analysis of an engineering system, which has two units of different strengths in parallel and one unit as a cold standby unit. Failure times for all the units have negative exponential distribution whereas their repair times have general distribution. Single server caters the need for the system. The effectiveness analysis of the system is done by using regenerative point technique. The different measures of effectiveness such as mean sojourn time, mean time to system failure, availability, busy period, etc, are derived. Cost factors also taken into consideration.

Keywords