DOI QR코드

DOI QR Code

Analysis of Parameters on Partial Discharges from Insulation Defects of used Hydro Generator Stator Windings

수력발전기 고정자 노후권선의 모의결함 시편에 대한 부분방전 파라미터 변화 분석

  • 오봉근 (한국수자원공사 수자원연구원) ;
  • 김현일 (한국수자원공사 수자원연구원) ;
  • 강성화 (충청대학 소방안전과) ;
  • 임기조 (충북대학교 전기전자컴퓨터공학부)
  • Published : 2007.07.01

Abstract

Partial discharge(PD) test for simulated insulation defects of used hydro generator stator winding was conducted to analyze the PD Parameters. Simulated insulation defects are classified by 5 types corona, slot, internal, multi and aging defect. Phase resolved partial discharge, statistical parameter (skewness, kurtosis), PD magnitude as a function of the test voltage(Q-V curve) and PD magnitude change under test voltage for 2 minutes are used as PD parameters. The analysis of PD parameters by 4 types are proved to be useful methods. In particular, PD parameter characteristics of aging defect could help to assess the aging condition of stator winding because aging defect has more weak insulation strength than other insulation defects : PD distribution is wide and flat, PD rises rapidly near $0^{\circ}\;and\;180^{\circ}$ and Q-V curve rises sharply and then gently drops.

Keywords

References

  1. I. M. Culbert, H. Hhirani, and G. C. Sone, 'Handbook to assess the insulation condition of large rotating machines', EPRI publication EL-5036, Vol. 16, 1989
  2. N. C. Sahoo, M. M. A. Salama, and R. Bartnikas, 'Trends in partial discharge pattern classification : A survey', IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 12, No. 2, p. 248, 2005 https://doi.org/10.1109/TDEI.2005.1430395
  3. 박성희, 임기조, 강성화, '견인전동기용 고정자 코일의 Off-line 부분방전 진단을 위한 NN의 적용', 전기전자재료학회논문지, 18권, 8호, p 766, 2005
  4. F. H. Kreuger, 'Partial Discharge Detection in High-Voltage Equipment', Butterworths, 1989
  5. 박재준, 이성룡, 문대철, '고압전동기 고정자권선의 PRPD 부분방전 결함선호 해석', 전기전자재료학회논문지, 19권, 10호, p. 942, 2006 https://doi.org/10.4313/JKEM.2006.19.10.942
  6. B. Yue, X. Chen, Y. Cheng, J. Song, and H. Xie, 'Diagnosis of stator winding insulation of large generator based on partial discharge measurement', IEEE Transactions on Energy Conversion, Vol. 21, No. 2, p. 387, 2006 https://doi.org/10.1109/TEC.2006.874223