Noise Test and Evaluation of a 750kW Wind Turbine Generator

750kW 풍력발전기의 소음실증

  • 김석현 (강원대학교 메카트로닉스공학과) ;
  • 허욱 (강원대학교 대학원 기계메카트로닉스공학과) ;
  • 이현우 (강원대학교 대학원 기계메카트로닉스공학과)
  • Published : 2007.08.31

Abstract

This study introduces an environmental noise evaluation procedure and results for a wind turbine (W/T) system. Test and evaluation are required by the international standard IEC 61400-11 in the aspect of environmental effect. Test and evaluation are performed on U-50 WT model which is first developed by the domestic W/T manufacturer. W/T test model is under operation in Daekwanryung wind test site. An integrated monitoring system in the test site is utilized for the evaluation. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level are estimated and compared with those of other similar size WT under the wind speeds required by international standard.

Keywords