An Experimental Study on Laminar Heat Transfer in Flat Aluminum Extruded Tubes Having Small Hydraulic Diameter

  • Kim, Nae-Hyun (Department of Mechanical Engineering, University of Incheon) ;
  • Ham, Jung-Ho (Department of Mechanical Engineering, University of Incheon) ;
  • Kim, Do-Young (Department of Mechanical Engineering, University of Incheon)
  • Published : 2007.06.30

Abstract

Laminar heat transfer experiments were conducted in flat extruded aluminum tubes. Three different flat tubes-two with smooth inner channel, one with micro-finned inner channel-were tested. Smooth tube data were in reasonable agreement with the predictions by simplified theoretical models. The heat transfer coefficients of the micro-fin tube were significantly smaller than those of the smooth tube. The reason was attributed to the decelerating flow in the inter-fin region. Heat transfer correlations were developed from the data.

Keywords

References

  1. Webb, R. L. and Jung, S. H., 1992, Air-side performance of enhanced brazed aluminum heat exchangers, ASHRAE Trans, BA-92-4-2, pp. 391-401
  2. Wang, C. C., Webb, R. L., and Chi, K.Y., 1998, Data reduction for air-side performance of fin-and-tube heat exchangers, Exp. Thermal Fluid Science, Vol. 21, pp.218-226
  3. Farrell, P., Wert, K., and Webb, R. L., 1991, Heat transfer and friction characteristics of turbulent radiator tubes, SAE Technical Paper Series, No.910197
  4. Sieder, E. N. and Tate, G. E., 1936, Heat transfer and pressure drop of liquids in tubes, Ind. Eng. Chem., Vol. 28. pp.1429-1435 https://doi.org/10.1021/ie50324a027
  5. Kline, S. J. and McClintock, F. A, 1953, The description of uncertainties in single sample experiments, Mechanical Engineering, Vol. 75, pp.3-9
  6. Shah, R. K. and London, A. L., 1978, Laminar flow forced convection in ducts, Advances in Heat Transfer, Supplement 1, edited by T. F. Irvine and J. P. Hartnett., Academic Press
  7. Soliman, H. M., Chau, T. S., and Trupp, A. C., 1980, Analysis of laminar heat transfer in internally finned tubes with uniform outside wall temperature, Journal of Heat Transfer, Vol. 102, pp.598-604 https://doi.org/10.1115/1.3244358