증분컨덕턴스 제어적용 태양광 인버터 실증시험에 관한 연구

A Study on Real Test of an Incremental Conductance MPPT Control Based Photovoltaic Inverter

  • 발행 : 2007.07.01

초록

In this paper, a 10kVA PV inverter applying Incremental Conductance(IncCond) method for maximum power point tracking WIS developed and its performance tests were carried out. Modeling and simulation of PV array and system controller was performed using PSCAD/EMTDC, an electromagnetic transient analysis program. After comparison and analysis of Perturbation & Observation (P & O) and IncCond method, a PV inverter based on IncCond method was designed and manufactured. Grid interface transient characteristics including start-up, normal operation, and fault operation were tested, which verified the usefulness of the proposed system. In the near future, commercialization process will proceed through additional extensive tests of transients.

키워드

참고문헌

  1. Mohammad A. S. Masoum, Hooman Dehbonei, and Ewald F. Fuchs, 'Theoretical and Explanation Analysis of Photovoltaic Systems With Voltage- and Current-Based Maximum Power-Point Tracking', IEEE Trans. on Energy Conversion, Vol. 17, No.4, December 2002, pp. 514-522 https://doi.org/10.1109/TEC.2002.805205
  2. L Zhang, A AI-Amoudi, Yunfei Bai, 'Real-time Maximum Pewer Point Tracking for Grid-Connected Photovoltaic Systems', Power Electronics and Variable Speed Drives, 18-19 September 2000, Conference Phiblication No. 475
  3. Manitoba HVDC Research Center, PSCAD/EMTDC Power System Simulation Software User's Manual, 1998
  4. Minwon Park and In-Keun Yu, 'A Novel Real-Time Simulation Technique of Photovoltaic Generation Systems Usng RTDS', IEEE Trans. on Energy Conversion, Vol. 19, No.1, March 2004
  5. S.K.Kim, E.S.Kim, 'PSCAD/EMTDC를 이용한 계통연계형 태양광발전시스템의 모델링 및 모의해석', 대한전기학회논문지 54A권 3호, 2005년 3월, pp. 107-116