Abstract
This study is to propose the basic data for deciding remodeling of wornout educational facilities. In order of it, the indoor environmental standard, the actual conditions of thermal environment and sound insulation of walls were examined through field measurement in the subjected open elementary school(J school) and modernization model of elementary school(Y school) which they are located in Seoul. As the result, standard for indoor environmental factors of educational facilities which is established by Ministry of Education is not subdivided into indoor environmental performances considering usages and characteristics of classrooms for comfortable indoor environment. The vertical temperature difference in general classroom and in open classroom showed to be $11.2^{\circ}C$ and $12.1^{\circ}C$ respectively, while indoor temperature of special classroon was, on the whole, higher than that of any other classroom due to its specific heat flux of wall materials. The sound insulation performance of the masonry brick wall of classroom satisfied the minimum standard of AIJ, Architectural Institute of Japan, in the open elementary school and the modernization model of elementary school. That is to say, the movable partition wall between the classroom and the corridor disturbed students in their class in the open school.